Sartorius Secura513 1S Toploading Balance 510G x 0 001G Internal Calibration Review & Buying Guide
The Sartorius Secura513 1S Toploading Balance 510G x 0 001G Internal Calibration is a Sartorius precision balance rated to 510 g with 0.001 g readability. This guide covers its specifications, how this class of instrument works, how to choose capacity and resolution, calibration practice, and where to buy it in the USA.
🇺🇸 BUY FROM THE USA
The Sartorius Secura513 1S Toploading Balance 510G x 0 001G Internal Calibration is a Sartorius precision balance with a 510 g capacity and 0.001 g readability (510,000 display divisions). This guide explains what the Sartorius Secura513 measures, how this class of instrument works, how to match capacity and resolution to your application, what calibration it needs, and where to buy it in the United States.
Sartorius Secura513 specifications
| Manufacturer | Sartorius |
|---|---|
| Model | Sartorius Secura513 |
| Instrument class | Precision balance |
| Capacity | 510 g |
| Readability (d) | 0.001 g |
| Display divisions | 510,000 |
| Availability | In stock — ships from the USA |
| Warranty | Full Sartorius manufacturer warranty |
| Calibration service | NIST-traceable, Cypress TX facility |
What is a precision balance?
A precision balance (also called a top-loading balance) measures mass at readabilities between 1 g and 0.001 g, with a larger capacity and faster stabilisation than an analytical balance and usually no full draft shield. The Sartorius Secura513 offers 510 g capacity at 0.001 g readability — 510,000 display divisions. It is the workhorse instrument for formulation, QC sampling, education, and any task where analytical-grade resolution is unnecessary but 0.1 g bathroom-scale accuracy is not enough.
How a precision balance works
Precision balances above about 0.01 g resolution may use either electromagnetic force restoration or a high-quality single-point strain-gauge load cell. A single-point cell is machined from one aluminium block with strain gauges bonded to flexure sections; it is corner-load compensated so a sample placed off-centre on the pan reads the same as one placed in the middle. EMFR models cost more but drift less with temperature and settle faster.
Sartorius Secura513 capacity in other units
Capacity is quoted as 510 g. The same capacity expressed in the units buyers commonly work in:
| Grams (g) | 510 |
|---|---|
| Kilograms (kg) | 0.51 |
| Pounds (lb) | 1.124 |
| Ounces (oz) | 17.99 |
| Troy ounces (ozt) | 16.397 |
| Carats (ct) | 2,550 |
How to choose: what actually matters on a precision balance
These are the specifications that change the outcome of a purchase, in the order they should be evaluated.
- Capacity headroom. Include the tare weight of your container. A 3200 g balance holding a 500 g beaker only leaves 2700 g of usable range.
- Divisions as a quality signal. Capacity ÷ readability gives display divisions. Consumer scales run 1,000–3,000 divisions; laboratory precision balances typically run 30,000–320,000. More divisions means the manufacturer is confident in the load cell's linearity across the range.
- Stabilisation time. Published figures are typically 1–3 seconds for a good top-loader. On high-throughput lines this dominates operator time far more than resolution does.
- Interfaces. RS-232, USB, or Ethernet output matters for GMP/ISO environments that require an unedited electronic weight record.
- Legal for trade. If you sell by weight, the instrument must be NTEP-certified (Handbook 44 Class II or III) and locally sealed. Laboratory accuracy alone does not make a scale legal for trade.
- Draft shield option. At 0.001 g you will want one, even though the balance ships without it.
Getting accurate results from the Sartorius Secura513
Most complaints about scale accuracy are traceable to installation and procedure rather than to the instrument. The following practices apply directly to the Sartorius Secura513.
- Calibrate with a weight close to full capacity — span error is proportional to load, so a 100 g weight cannot validate a 3200 g range.
- Use an ASTM Class 1 or Class 2 test weight for balances at 0.001–0.01 g. Handbook 105-1 guidance is that the weight's tolerance should not exceed 1/3 of the scale's smallest division.
- Keep the balance out of HVAC airflow and off shared benches with centrifuges or stirrers.
- Re-zero before every weighing rather than trusting an old tare; drift over hours is normal and expected.
- Readability (also written as d, or the display division) is the smallest change in mass the display can show. It is not the same as accuracy: a balance reading to 0.01 g may still carry a linearity error of ±0.02 g. Accuracy is bounded by readability, repeatability (standard deviation of repeated loads), and linearity combined.
Where the Sartorius Secura513 is used
- Formulation and batching in food, cosmetics, and chemical production
- Incoming QC sample weighing and yield checks
- Education: physics, chemistry, and biology teaching labs
- Density determination with a below-balance hook or density kit
- Coating, plating, and filter-weight differential measurement
Calibration and verification requirements
Every weighing instrument drifts. Span error grows with load, zero drifts with temperature, and mechanical wear changes both. Two separate activities keep a scale trustworthy:
- Verification — placing a certified test weight on the scale and recording the reading, without changing anything. This is a check, and it is the record an auditor wants to see.
- Calibration (adjustment) — correcting the instrument's span so it reads the certified value. This should be done by a qualified technician with traceable standards and documented afterwards.
Guidance in NIST Handbook 105-1 is that the test weight's tolerance should be no more than one third of the scale's smallest division; many quality systems tighten that to one tenth. In practice that means an ASTM Class 1 weight for balances reading to 0.001 g, Class 2 for 0.01 g, and Class 4 or 6 for industrial platform and crane scales. Typical intervals are annual for general industrial use, semi-annual or quarterly under ISO 9001 or GMP, and immediately after any move, overload, or suspected impact.
Certified calibration and repair for the Sartorius Secura513 is available through our calibration service and repair service, and locally in Texas through Houston scale services.
Is the Sartorius Secura513 legal for trade?
In the United States, a scale used to determine the price a customer pays must be certified under the National Type Evaluation Program (NTEP) and sealed by the state or local weights-and-measures authority. NTEP evaluates a device against NIST Handbook 44 and assigns an accuracy class — Class I and II for laboratory and jewelry work, Class III for retail and general commercial weighing, Class IIII for coarse industrial use. Laboratory accuracy on its own does not make an instrument legal for trade, and a certified instrument loses legal standing if the seal is broken or the device is moved without re-verification. If weight determines money changing hands in your operation, confirm the NTEP Certificate of Conformance number before you buy.
Where to buy the Sartorius Secura513 in the USA
The Sartorius Secura513 1S Toploading Balance 510G x 0 001G Internal Calibration is stocked in the United States by MNM Scales, a specialty weighing-systems dealer operating since 1998 out of Cypress, Texas. Buying from a scale specialist rather than a general marketplace matters for three concrete reasons on precision equipment:
- Calibration on arrival. A scale shipped without a pre-delivery check frequently needs adjustment out of the box, especially after air freight.
- Warranty registration. The manufacturer warranty is registered in the buyer's name, which matters if a load cell fails in year two.
- Service capability. Repair and recertification happen in-house rather than through a return-to-manufacturer cycle.
Our sister operations cover the same catalog: MNM Scales for the full multi-brand range and AllscalesUSA for nationwide sales and service. Both ship free to the mainland USA.
Frequently asked questions
What is the capacity and readability of the Sartorius Secura513?
The Sartorius Secura513 is rated to 510 g with 0.001 g readability, which works out to 510,000 display divisions across the range. Remember to subtract the weight of any container from capacity when planning your usable range.
What is the difference between readability and accuracy on the Sartorius Secura513?
Readability is the smallest increment the display can show — 0.001 g on the Sartorius Secura513. Accuracy is how close the reading is to true mass, and it is limited by three things together: readability, repeatability (the standard deviation of repeated identical loads), and linearity (deviation from a straight line across the range). A scale can display one more digit than it can reliably guarantee, so the specification sheet's repeatability and linearity figures matter as much as the readability number.
What test weight should be used to calibrate the Sartorius Secura513?
Use a certified weight at or near full capacity, with a tolerance no greater than one third of the scale's smallest division (0.001 g here). For laboratory resolutions that means ASTM E617 Class 1 or Class 2; for industrial platform and crane scales, Class 4 or Class 6 is standard. Verifying only at low load cannot detect span error, because span error is proportional to the load applied.
How often should the Sartorius Secura513 be calibrated?
Annually for general commercial and industrial use; semi-annually or quarterly where ISO 9001, GMP, HACCP, or a customer specification requires it; and immediately after any relocation, suspected overload, or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction, which is usually annual.
Does the Sartorius Secura513 come with a warranty, and is it in stock?
Yes. Units are supplied new with the full Sartorius manufacturer warranty registered in the buyer's name, and the Sartorius Secura513 is currently in stock for shipment within the mainland USA. Check current pricing and stock for the Sartorius Secura513.
Can the Sartorius Secura513 be repaired rather than replaced?
In most cases yes. The common failure points on this class of instrument are the load cell, the keypad membrane, the display ribbon, and the power supply — all replaceable. Repair is generally worthwhile when the instrument's replacement cost is high relative to the repair, and every repair should be followed by a full recalibration and a new certificate.
Summary
The Sartorius Secura513 1S Toploading Balance 510G x 0 001G Internal Calibration is a Sartorius precision balance rated to 510 g at 0.001 g readability. Match capacity to your heaviest load plus its container, choose readability at least ten times finer than the smallest difference you need to detect, verify with a certified weight on a documented interval, and confirm NTEP certification if weight will determine price. Ordering, warranty registration, and certified calibration for the Sartorius Secura513 are all handled in the USA.
Direct product link: https://mnmscales.com/product/sartorius-secura513-1s-toploading-balance-510g-x-0-001g-internal-calibration/
Technical questions about the Sartorius Secura513? Call 832-290-3120 or message a scale specialist, Monday – Friday, 10 AM – 4 PM CT.
Explore related categories
Keep researching with the category, manufacturer and accessory hubs this model belongs to: