Shipping Scales
A shipping scale is a bench or platform scale used to determine parcel weight for carrier billing, usually 70 lb to 400 lb capacity with 0.1–0.2 lb increments and a USB or serial output that feeds UPS WorldShip, FedEx Ship Manager or USPS Click-N-Ship directly.
Also called: parcel scale · postal scale · package scale · UPS scale · FedEx scale
Shipping Scales in stock
Shipped from the United States with the manufacturer's warranty. Prices shown are current US pricing; call 832-290-3120 for volume quotes or application help.
How shipping scales work and how to specify them
Carriers bill on the greater of actual weight and dimensional weight, and they audit. A parcel that ships light on your scale and heavy on theirs generates an adjustment charge weeks later, so the practical requirement for a shipping scale is agreement with the carrier's certified equipment — which means calibration, not just resolution.
Choose capacity by your heaviest routine parcel plus 25%: 70 lb covers most e-commerce, 150 lb covers freight-adjacent boxes, and 400 lb platform units cover crated goods. Increment should match how the carrier rounds; billing in whole pounds does not require 0.01 lb resolution.
A USB HID output makes the scale appear to shipping software as a keyboard-class weight source with no drivers, which is the least troublesome integration for a multi-station shipping bench. Every instrument can ship with a NIST-traceable calibration certificate performed in our Cypress, Texas service lab, and we handle on-site calibration and repair across the Houston metro.
Shipping scale selection
| Application | Typical capacity | Typical readability | Notes |
|---|---|---|---|
| Letters, poly mailers, small parcels | 10–35 lb | 0.005–0.01 lb | Desktop postal scale |
| E-commerce boxes | 70–100 lb | 0.02–0.05 lb | USB output for WorldShip |
| Heavy cartons | 150–200 lb | 0.05–0.1 lb | Large platter |
| Crates and freight | 400 lb+ | 0.1–0.2 lb | Floor-level platform |
What to check before you buy
- Carrier agreement. Verify annually with certified test weights so your manifest weights survive a carrier audit.
- Output type. USB HID for plug-and-play; RS-232 where existing shipping stations are already wired.
- Platter size. Overhanging boxes read low — size the platter to your largest carton.
- Legal for trade. Required if you charge customers by weight rather than simply paying a carrier.
- Hold and tare. Useful for irregular or shifting contents and for reusable outer packaging.
Shipping Scales buyer's guide: how to choose the right model
Work through these criteria in order. Each one narrows the shortlist, and getting them in this sequence is what prevents an expensive mismatch between the instrument and the job.
1. Confirm shipping scales are the right class
You are rating parcels for carrier billing weight. Bench or floor platform with parcel-friendly readability. If that does not describe your job, the wrong class will cost you twice — selling goods by weight at a counter, or fine lab work.
Key criterion 1
Round-up rules mean 0.1 lb readability is enough for most carriers — do not overpay for resolution.
Key criterion 2
Confirm capacity covers your heaviest single parcel plus the packaging.
Key criterion 3
USB or RS-232 output lets the weight drop straight into your shipping software.
Key criterion 4
Dimensional weight matters as much as scale weight; measure and store box dimensions too.
2. Size the capacity with headroom
This class runs 70 lb – 400 lb. Work from your heaviest realistic load including packaging, pallet or container, then step up to the next capacity rather than running an instrument at its ceiling every day.
3. Set readability from the smallest thing you measure
Typical readability here is 0.02 lb – 0.2 lb. Choose resolution from the smallest increment you must resolve — not the largest weight — and remember that finer resolution means a slower, more environment-sensitive reading.
4. Match the instrument to the environment
Fulfilment benches, mail rooms, e-commerce packing. Decide on washdown rating, mounting and display position before comparing prices; an under-specified enclosure is the most common reason a scale is replaced early.
5. Decide whether it must be legal for trade
NTEP only needed if you sell by weight, not for carrier rating. If money changes hands on the basis of the weight, you need an approved model sealed by your state weights-and-measures authority; if it is an internal process check, you do not.
6. Plan data, service and calibration
Choose the data path you will actually use — printout, serial, USB or PLC — and budget annual calibration. We calibrate, certify and repair shipping scales in our Cypress, Texas lab and on site across the Houston metro.
Shipping Scales vs Bench Scales vs Floor Scales vs NTEP Scales
These categories overlap in capacity but not in how the load is presented. Compare the rows below, then follow the link to the category that matches your application.
| Category | How it takes the load | Typical capacity | Typical readability | Use cases | Choose it when | Legal for trade |
|---|---|---|---|---|---|---|
| Shipping Scales (this page) | Bench or floor platform with parcel-friendly readability | 70 lb – 400 lb | 0.02 lb – 0.2 lb | Fulfilment benches, mail rooms, e-commerce packing | You are rating parcels for carrier billing weight | NTEP only needed if you sell by weight, not for carrier rating |
| Bench Scales | Bench-top platform with a separate or integral indicator | 10 lb – 500 lb | 0.001 lb – 0.1 lb | Packing benches, production cells, receiving desks | One person can lift the item onto a waist-height platform | NTEP versions widely available |
| Floor Scales | Low-profile platform on the floor, four load cells | 1,000 lb – 20,000 lb | 0.2 lb – 5 lb | Warehouses, docks, pallet and drum handling | Loads arrive on pallets, carts or drums and can be rolled or forked on | NTEP versions standard on most capacities |
| NTEP Scales | Any class of scale holding a Certificate of Conformance | Depends on class | Class II/III division limits apply | Anywhere goods change hands by weight | You buy, sell or bill by weight | This is the category — always verify the CoC number |
Certifications, datasheets and documentation
What we can certify for shipping scales, and the documents you can download before you raise a purchase order.
Authorized A&D Weighing dealer
Sold as an authorized dealer since 1998, so every unit carries the full manufacturer warranty and factory firmware — not grey-market stock.
NIST-traceable calibration certificate
Any instrument can ship with a calibration certificate produced in our Cypress, Texas lab using mass standards traceable to NIST, with as-found and as-left values recorded.
NTEP legal-for-trade options
Models in this category are available with an NTEP Certificate of Conformance evaluated against NIST Handbook 44, ready for sealing by your state weights-and-measures authority.
ASTM E617 / OIML R111 test weights
Verification weights are supplied in ASTM Class 1–6 or OIML E2–M3 tolerances, sized so the standard's tolerance stays inside one third of the scale's smallest division.
In-house repair & on-site service
Factory-trained technicians repair, adjust and re-certify weighing equipment in our own Texas workshop and on-site across the Houston metro.
Shipping Scales — specification datasheet (PDF)
Capacity and readability selection table, buying criteria, certification notes and the answers to the questions purchasing always asks — two pages, no email required.
Download datasheetInstruction manuals hosted here
Tell us the model and we will send the manufacturer's manual and declaration of conformity — call 832-290-3120.
All scale manuals and literatureShipping Scales glossary — the specification terms explained
Every term used in the tables above, defined the way NIST Handbook 44, ASTM E617 and OIML R76/R111 use it.
- Accuracy
- How close a displayed weight is to the sample's true mass. Accuracy is limited by readability, repeatability and linearity together, so a scale can never be more accurate than its specification sheet's worst of those three figures.
- ASTM E617
- The American standard that defines tolerance classes for mass standards. Class 1 weights are the tightest commonly used for laboratory balances, Class 2 for 0.01 g balances, and Classes 4 and 6 for industrial platform and crane scales.
- Calibration
- Adjusting a scale's span so it reads a certified test weight correctly, documented with as-found and as-left values. Distinct from verification, which records a reading without changing anything.
- Capacity
- The maximum mass a scale is rated to weigh. Usable capacity is the rated capacity minus every container, fixture or platform that sits on the pan, because tare does not add capacity back.
- GLP output
- A printout or data record that includes date, time, instrument identification and calibration status, as required by Good Laboratory Practice and comparable quality systems for audit trails.
- Legal for trade
- A device certified and sealed for use in commercial transactions where weight determines price. In the United States this requires an NTEP Certificate of Conformance and a seal from the state or local weights-and-measures authority.
- NIST Handbook 44
- The United States specification, tolerance and technical requirement document for commercial weighing and measuring devices. NTEP evaluates devices against it.
- NTEP
- The National Type Evaluation Program, run by NCWM, which tests weighing devices against NIST Handbook 44 and issues a Certificate of Conformance with an accuracy class. Required for legal-for-trade use.
- NTEP accuracy class
- The class assigned to a certified device: Class I and II for laboratory, analytical and jewelry work, Class III for retail and general commercial weighing, and Class IIII for coarse industrial use.
- OIML R76 / R111
- The international recommendations for non-automatic weighing instruments (R76) and for weights of classes E1 to M3 (R111). They are the international counterparts to NIST Handbook 44 and ASTM E617.
- RS-232
- The serial data interface most weighing instruments use to send weight readings to a printer, PC or dispensing controller. Continuous streaming output is required by closed-loop powder dispensers.
- Verification
- Applying a certified test weight and recording the reading without adjusting the instrument. This is the record an auditor asks for, and it is not the same as calibration.
Shipping Scales — frequently asked questions
- What size shipping scale do I need?
- For typical e-commerce parcels a 70 lb x 0.02 lb scale is the standard choice. Move to 150–400 lb only if you regularly ship heavy cartons or crates.
- Do shipping scales work with UPS and FedEx software?
- Yes — a scale with a USB HID or RS-232 output is recognized by UPS WorldShip, FedEx Ship Manager, ShipStation and most other shipping platforms as a weight input device.
- Does a shipping scale need to be legal for trade?
- Not to pay a carrier. It does if you bill your own customers by weight, in which case you need an NTEP-certified scale sealed by your state.
- Why does my parcel weight differ from the carrier's?
- Usually either calibration drift or dimensional weight. Verify your scale against a certified test weight, and remember carriers bill the greater of actual and dimensional weight.