Adam Equipment GFK 165aH – Bench Scale
Check weighing applications are trouble free with amber, green and red indicators to show the operator if the item is under, over or at the preset limits. A stainless steel top pan offers ample weighing surface and a standard pillar allows for easy mounting of the indicator if desired. The GFK includes a RS-232 interface with date and time, bright backlit display with capacity tracker, a built-in rechargeable battery and external power supply.
The GFK offers all the features needed for weighing, check weighing with LED limit indicators and parts counting application with fully selectable sample or unit weight. Built tough for a variety of industries the GFK can meet the demands of warehouse, production floor or even medical applications.
Special Features:
- Auto sleep / power down function to save battery life
- 2 Year Manufacturer’s Warranty
- 5 weighing units (kg, g, lb, oz, lbs:oz)
- Automatic memory accumulation
- Pre-set counting with alarm
- Date and time
- Adjustable filters
- Full range tare
- Internal counting resolution 1:400,000
- Check-weighing with low and high limits
- Check weighing LED bar graph
- Capacity tracker
- Large backlit LCD display
- Overload protection
- Non-slip adjustable levelling feet
- Large stainless steel platform
- Pillar mounted
- Full colour coded keypad with numeric entry
- Precision load cell technology
- Simple user-friendly operation
- Splashproof to protect from accidental spills
- Easy access to the rechargeable battery
- RS-232 bi-directional interface
- External calibration
- Rechargeable battery up to 90 hours operation
- AC Adapter
- Applications: Parts counting, Percentage weighing, Animal / dynamic weighing, Check weighing, Check counting
| Adam Equipment – GFK 165aH | |
|---|---|
| Capacity | 165 lbs / 75 kg |
| Readability | 0.002 lb / 1 g |
| Pan Size | 15.7 × 19.7″ / 400 × 500 mm |
| Calibration | Automatic External |
| Display | Backlit Green display with 25mm digits and capacity tracker |
| Operating Temperature | –10°C – 40°C / 14°F – 104°F |
| Housing | ABS Plastic Indicator and Stainless steel pan |
Why buy from EK1200i.com
- Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
- Free fast shipping within the mainland USA
- In-house NIST-traceable calibration available before shipment on request
- Live phone and email support from working scale technicians in Cypress, Texas
- Full-service calibration and repair lab for the life of your scale
Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.
Need bulk pricing? Contact us for special pricing on volume orders.
Specifications
- Manufacturer
- Adam Equipment
- Model
- Adam Equipment
- Instrument class
- Bench scale
- SKU / Part number
- ADAME-GFK165AH
- Price (USD)
- $999.00
- Availability
- In stock — ships from the USA
- Shipping
- Free ground shipping, mainland USA
- Warranty
- Full manufacturer warranty, registered to the buyer
- Calibration
- NIST-traceable, performed in Cypress, TX
What is a bench scale, and how does this one work?
A bench scale is a mid-capacity platform scale designed to sit on a work surface, typically covering 5 lb to 300 lb with a stainless or painted-steel platter. It is the standard instrument for shipping, receiving, portioning, and checkweighing.
Most bench scales use a single-point aluminium or stainless load cell mounted under the centre of the platter. The cell is corner-load compensated during manufacture so a parcel placed at any corner of the platform reads the same. The indicator applies filtering (digital averaging) to reject vibration, which is why a heavier filter setting gives a steadier but slower reading.
Where the Adam Equipment is used
- •Shipping and receiving, parcel and freight rating
- •Food portioning and ingredient batching
- •Checkweighing on packaging lines
- •Retail back-of-house and inventory control
- •Laboratory and industrial general-purpose weighing
Getting accurate results
- •Place the scale on a rigid, level surface; a flexing table introduces reading instability that no filter setting will fix.
- •Calibrate with a weight at or near capacity, and verify at mid-range afterwards to check linearity.
- •Check corner (shift) error quarterly: place the same test weight at each corner of the platter; readings should agree within one division.
- •Keep the platter clean underneath — debris bridging the platter to the base creates a mechanical shunt and false low readings.
Frequently asked questions about the Adam Equipment
What are the capacity and readability of the Adam Equipment?
Capacity and readability for the Adam Equipment are listed in the specification table above.
What test weight is needed to calibrate the Adam Equipment?
A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.
How often should the Adam Equipment be calibrated?
Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.
Is the Adam Equipment legal for trade?
A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.
What is the difference between readability and accuracy?
Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.
How fast does the Adam Equipment ship, and can it be repaired?
In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.
Adam Equipment manual summary and troubleshooting
Unpacking and installation
Unpack on the bench where the instrument will live, fit the platter or pan, and connect the supplied adapter. Level the instrument using the feet until the bubble is centred, then let it power up and warm through before the first weighing.
Calibration and verification
Run the span calibration routine with a certified test weight at or near full capacity, then verify with a second weight near one third of capacity. Record both readings and the date in a calibration log.
Error codes and symptoms
| Symptom | Cause and remedy |
|---|---|
| Unstable / flashing reading | Air movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading. |
| Over-capacity indication (E, EEEE, or ---- ) | Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero. |
| Will not zero at power-up | Something is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle. |
| Calibration fails or rejects the weight | Wrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up. |
| Drifting reading over minutes | Thermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders. |
Care and re-verification
Keep the platter clean and dry, avoid shock loading, store certified test weights in their case and re-verify after any move.
Need the printed PDF? The official Adam Equipment Co. Ltd manual library is at Adam Equipment Co. Ltd documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.