Andweighing ADFCI-0806-2L AD FC-I Series FC-1000i Counting Scale, 2 lb. x 0.0002
$982.11
Capacity 2 lb × readability 0.0002 lb.
Counting scales convert weight into piece count using an average piece weight, which speeds up inventory, kitting and small-parts picking. Internal resolution matters more than displayed capacity.
At a glance
- Model: ADFCI-0806-2L
- Brand: MNM Scales
- Category: Counting Scale
Not sure this is the right model for your application? Our technicians match scales to real-world jobs every day and will confirm capacity, readability and legal-for-trade requirements before you order.
Why buy from EK1200i.com
- Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
- Free fast shipping within the mainland USA
- In-house NIST-traceable calibration available before shipment on request
- Live phone and email support from working scale technicians in Cypress, Texas
- Full-service calibration and repair lab for the life of your scale
Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.
Need bulk pricing? Contact us for special pricing on volume orders.
Specifications
- Manufacturer
- MNM Scales
- Model
- ADFCI-0806-2L
- Instrument class
- Parts counting scale
- Capacity
- 2 lb
- Readability (d)
- 0.0002 lb
- Display divisions
- 10,000
- SKU / Part number
- MNMSC-ADFCI-0806-2L-2LB-00002
- Price (USD)
- $982.11
- Availability
- In stock — ships from the USA
- Shipping
- Free ground shipping, mainland USA
- Warranty
- Full manufacturer warranty, registered to the buyer
- Calibration
- NIST-traceable, performed in Cypress, TX
Capacity in other units
- Grams (g)
- 907.185
- Kilograms (kg)
- 0.9072
- Pounds (lb)
- 2
- Ounces (oz)
- 32
- Troy ounces (ozt)
- 29.167
- Carats (ct)
- 4,535.9
What is a parts counting scale, and how does this one work?
A parts counting scale converts weight into piece count by dividing total load by an average piece weight (APW) learned from a sample. The ADFCI-0806-2L has a 2 lb capacity and 0.0002 lb weighing readability. Counting accuracy depends far more on the consistency of the parts and the size of the sample than on the scale's weighing resolution.
You place a known quantity — typically 10, 25, 50, or 100 pieces — on the pan and enter that number. The scale computes APW = sample weight ÷ sample count, then reports count = total weight ÷ APW. Better counting scales add automatic APW re-optimisation: as you add more parts, the scale recalculates APW from the larger sample, progressively reducing the error inherited from the initial sample.
Where the ADFCI-0806-2L is used
- •Cycle counting and inventory reconciliation in warehousing
- •Kitting and BOM verification on assembly lines
- •Fastener, electronic component, and small-hardware distribution
- •Pharmacy tablet and capsule counting
- •Shipping verification: confirming carton piece counts before dispatch
Getting accurate results
- •Always sample from the same batch you are counting. Different production lots have different mean piece weights.
- •Tare the empty bin before sampling so container weight never enters the APW calculation.
- •For high-value inventory, verify a known count of 100 pieces before running a full cycle count.
- •Re-establish APW whenever the part number, supplier, or lot changes — a stored APW is only valid for the lot it was learned from.
- •Readability (also written as d, or the display division) is the smallest change in mass the display can show. It is not the same as accuracy: a balance reading to 0.01 g may still carry a linearity error of ±0.02 g. Accuracy is bounded by readability, repeatability (standard deviation of repeated loads), and linearity combined.
Frequently asked questions about the ADFCI-0806-2L
What are the capacity and readability of the ADFCI-0806-2L?
The ADFCI-0806-2L is rated to 2 lb with 0.0002 lb readability, which is 10,000 display divisions across the range. Subtract the mass of any container or fixture from capacity to get your usable weighing range, because tare does not add capacity back.
What test weight is needed to calibrate the ADFCI-0806-2L?
A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division (0.0002 lb here), per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.
How often should the ADFCI-0806-2L be calibrated?
Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.
Is the ADFCI-0806-2L legal for trade?
A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.
What is the difference between readability and accuracy?
Readability is the smallest increment the display can show — 0.0002 lb on the ADFCI-0806-2L. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.
How fast does the ADFCI-0806-2L ship, and can it be repaired?
In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.
ADFCI-0806-2L manual summary and troubleshooting
Unpacking and installation
Fit the platter, level the instrument and charge the internal battery fully before the first counting session. Set the counting resolution to its finest setting for small parts.
Calibration and verification
Calibrate weight first, then sample piece weight with the largest practical sample (100 pieces where possible). Re-sample whenever the part, plating or supplier changes.
Error codes and symptoms
| Symptom | Cause and remedy |
|---|---|
| Count is a few pieces out | Sample too small or piece weight varies. Increase the sample size and re-learn. |
| Count drifts as the bin fills | Container weight not tared. Tare the empty container before counting. |
| Unstable / flashing reading | Air movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading. |
| Over-capacity indication (E, EEEE, or ---- ) | Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero. |
Care and re-verification
Store sampled piece weights in memory channels, and re-verify against a hand count weekly.
Need the printed PDF? Call 832-290-3120 and we will email the exact manual revision for your serial number. See also the manual & documentation library.