Back to all A&D scales
    Brecknell PS25 Portable Parcel Shipping Scale 25 lbx0.2oz,Dual, Blue

    Brecknell PS25 Portable Parcel Shipping Scale 25 lbx0.2oz,Dual, Blue

    $110.00

    $44.00

    On Sale

    MSRP $110.00 — you save $66.00 (60% off)

    Brecknell PS25-B – Postal Scale

    The Brecknell PS25-Blue has a pink plastic finish with a 25 pound capacity. This simple weight-only electronic scale is perfect for letter and small parcel mail to ensure correct postage without overpayment. The low profile design is easy to use and store. Features a flip-up letter stand to hold large envelopes. Powered via four AAA battery or USB cable (both included). This model has a Units key to toggle between kg, g and lbs/oz, and an On/Off/Tare key. The USB interface is designed to work with most of the current USPS application packages to print postage locally from a PC. The scale transmits weight via the USB cable to the PC and the application program then takes the weight for postal calculations.

    Are you a scale reseller? Contact us
    Special Features:

    Dual Range
    Capacity:
    0 – 1 kg x 0.01 kg / 1 – 11.5 kg x 0.02 kg
    0 – 1000 g x 5 g / 1000 – 12000 g x 10 g
    0 – 2 lb x 0.1 oz / 2 – 25 lb x 0.2 oz

    • Low profile design
    • Flip up letter stand for large envelopes and tubes
    • Powered with 4 AAA batteries or via the included USB cable
    • USB interface connects to most USPS PC software applications
    Specifications:
    Brecknell – PS25-B
    Capacity 2 / 25 lb (Blue)
    Readability 0.1 / 0.2 oz
    Pan Size 8 x 6″
    Display 0.6″ / 15mm digits with backlight and Lo battery icon
    Operator Keys On/Off/Tare and Units
    Metric Capacity/Readability 0-1 kg x 0.1 kg / 1 – 12 kg x 0.02kg
    0 – 1,000 g x 5 g / 1,000 – 12,000 g x 10 g
    Power Four AAA batteries (included) or USB cable (included)
    Operating Temperature 32°F to 104°F / 0°C to 40°C
    Operating Humidity Range 20% to 90%
    Physical Dimensions 8.5″ L x 6″ W x 2″ H
    Packaging Dimensions/Weight 10.75″ x 8″ x 4″ / 2.25 lbs

    Why buy from EK1200i.com

    • Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
    • Free fast shipping within the mainland USA
    • In-house NIST-traceable calibration available before shipment on request
    • Live phone and email support from working scale technicians in Cypress, Texas
    • Full-service calibration and repair lab for the life of your scale

    Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.

    Request Quote
    Authorized A&D Dealer
    Free Mainland US Shipping
    Expert Support

    Need bulk pricing? Contact us for special pricing on volume orders.

    Specifications

    Manufacturer
    Brecknell
    Model
    PS25
    Instrument class
    Bench scale
    Capacity
    0.2 oz
    SKU / Part number
    BRECK-PS25-0.2OZ-02-3
    Price (USD)
    $44.00
    Availability
    In stock — ships from the USA
    Shipping
    Free ground shipping, mainland USA
    Warranty
    Full manufacturer warranty, registered to the buyer
    Calibration
    NIST-traceable, performed in Cypress, TX

    Capacity in other units

    Grams (g)
    5.67
    Kilograms (kg)
    0.0057
    Pounds (lb)
    0.012
    Ounces (oz)
    0.2
    Troy ounces (ozt)
    0.182
    Carats (ct)
    28.3

    What is a bench scale, and how does this one work?

    A bench scale is a mid-capacity platform scale designed to sit on a work surface, typically covering 5 lb to 300 lb with a stainless or painted-steel platter. The PS25 is rated to 0.2 oz. It is the standard instrument for shipping, receiving, portioning, and checkweighing.

    Most bench scales use a single-point aluminium or stainless load cell mounted under the centre of the platter. The cell is corner-load compensated during manufacture so a parcel placed at any corner of the platform reads the same. The indicator applies filtering (digital averaging) to reject vibration, which is why a heavier filter setting gives a steadier but slower reading.

    Where the PS25 is used

    • •Shipping and receiving, parcel and freight rating
    • •Food portioning and ingredient batching
    • •Checkweighing on packaging lines
    • •Retail back-of-house and inventory control
    • •Laboratory and industrial general-purpose weighing

    Getting accurate results

    • •Place the scale on a rigid, level surface; a flexing table introduces reading instability that no filter setting will fix.
    • •Calibrate with a weight at or near capacity, and verify at mid-range afterwards to check linearity.
    • •Check corner (shift) error quarterly: place the same test weight at each corner of the platter; readings should agree within one division.
    • •Keep the platter clean underneath — debris bridging the platter to the base creates a mechanical shunt and false low readings.

    Frequently asked questions about the PS25

    What are the capacity and readability of the PS25?

    The PS25 is rated to 0.2 oz. Subtract the mass of any container or fixture from capacity to get your usable weighing range, because tare does not add capacity back.

    What test weight is needed to calibrate the PS25?

    A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.

    How often should the PS25 be calibrated?

    Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.

    Is the PS25 legal for trade?

    A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.

    What is the difference between readability and accuracy?

    Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.

    How fast does the PS25 ship, and can it be repaired?

    In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.

    PS25 manual summary and troubleshooting

    Unpacking and installation

    Unpack on the bench where the instrument will live, fit the platter or pan, and connect the supplied adapter. Level the instrument using the feet until the bubble is centred, then let it power up and warm through before the first weighing.

    Calibration and verification

    Run the span calibration routine with a certified test weight at or near full capacity, then verify with a second weight near one third of capacity. Record both readings and the date in a calibration log.

    Error codes and symptoms

    SymptomCause and remedy
    Unstable / flashing readingAir movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading.
    Over-capacity indication (E, EEEE, or ---- )Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero.
    Will not zero at power-upSomething is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle.
    Calibration fails or rejects the weightWrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up.
    Drifting reading over minutesThermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders.

    Care and re-verification

    Keep the platter clean and dry, avoid shock loading, store certified test weights in their case and re-verify after any move.

    Need the printed PDF? The official Avery Weigh-Tronix / Brecknell manual library is at Avery Weigh-Tronix / Brecknell documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.

    Customer reviews for PS25