
BYK-Gardner 1636 124-1S Sartorius Entris Analytical Balance, 0.0001 g
$1697.00
Analytical balances read to 0.1 mg or finer inside a draft shield, for analytical chemistry, pharmacy and forensic work. Internal calibration and a stable bench are essential.
At a glance
- Brand: Sartorius
- Category: Analytical Balance
Not sure this is the right model for your application? Our technicians match scales to real-world jobs every day and will confirm capacity, readability and legal-for-trade requirements before you order.
Why buy from EK1200i.com
- Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
- Free fast shipping within the mainland USA
- In-house NIST-traceable calibration available before shipment on request
- Live phone and email support from working scale technicians in Cypress, Texas
- Full-service calibration and repair lab for the life of your scale
Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.
Need bulk pricing? Contact us for special pricing on volume orders.
Specifications
- Manufacturer
- Sartorius
- Model
- BYK-Gardner 1636
- Instrument class
- Analytical balance
- Capacity
- 0 g
- SKU / Part number
- SARTO-BYKGARDNER1636-0.0001G
- Price (USD)
- $1697.00
- Availability
- In stock — ships from the USA
- Shipping
- Free ground shipping, mainland USA
- Warranty
- Full manufacturer warranty, registered to the buyer
- Calibration
- NIST-traceable, performed in Cypress, TX
Capacity in other units
- Grams (g)
- 0
- Kilograms (kg)
- 0
- Pounds (lb)
- 0
- Ounces (oz)
- 0
- Troy ounces (ozt)
- 0
- Carats (ct)
- 0
What is a analytical balance, and how does this one work?
An analytical balance is a laboratory instrument that measures mass to 0.1 mg (0.0001 g) or finer inside an enclosed draft shield. The BYK-Gardner 1636 has a 0 g capacity and readability. At this resolution, air currents, temperature gradients, static charge, and building vibration all become measurable sources of error, which is why analytical balances use a windshield, a level indicator, and often internal motorised calibration.
Analytical balances use electromagnetic force restoration (EMFR), not a strain-gauge load cell. A coil sits in a permanent magnetic field; when mass is applied, a position sensor detects the deflection and the servo loop increases coil current until the pan returns to its null position. The current required is directly proportional to the applied force, so the reading is derived from a measured electrical quantity rather than from mechanical deformation. This is what makes 0.1 mg resolution and long-term stability possible.
Where the BYK-Gardner 1636 is used
- •Analytical chemistry: standard and reagent preparation, gravimetric analysis
- •Pharmaceutical QC and compounding under USP 41/1251
- •Materials research, catalyst and polymer sample preparation
- •Environmental testing: filter weighing for particulate (gravimetric PM) analysis
- •University teaching labs in quantitative analysis
Getting accurate results
- •Let the balance warm up. Most manufacturers specify 30–60 minutes from power-on before the first calibration; EMFR coil temperature affects the zero point.
- •Level the balance every time it is moved. A 1° tilt can change the reading measurably because the load vector is no longer vertical.
- •Handle weights and sample vessels with tongs or gloves. A fingerprint is roughly 0.1–1 mg — a full display division of error at 0.1 mg resolution.
- •Weigh by difference for hygroscopic or volatile samples: tare the closed container, add the sample, and re-weigh, rather than dispensing onto an open pan.
- •Ground plastic vessels or use an ioniser. Static on a plastic weigh boat can shift a reading by several milligrams and produce a slow, one-directional drift.
- •Readability (also written as d, or the display division) is the smallest change in mass the display can show. It is not the same as accuracy: a balance reading to 0.01 g may still carry a linearity error of ±0.02 g. Accuracy is bounded by readability, repeatability (standard deviation of repeated loads), and linearity combined.
Frequently asked questions about the BYK-Gardner 1636
What are the capacity and readability of the BYK-Gardner 1636?
The BYK-Gardner 1636 is rated to 0 g. Subtract the mass of any container or fixture from capacity to get your usable weighing range, because tare does not add capacity back.
What test weight is needed to calibrate the BYK-Gardner 1636?
A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.
How often should the BYK-Gardner 1636 be calibrated?
Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.
Is the BYK-Gardner 1636 legal for trade?
A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.
What is the difference between readability and accuracy?
Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.
How fast does the BYK-Gardner 1636 ship, and can it be repaired?
In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.
BYK-Gardner 1636 manual summary and troubleshooting
Unpacking and installation
Site the balance on a stone or dedicated anti-vibration bench away from doors, vents and direct sun. Fit the draft shield, pan support and pan, level the bubble, and allow at least 60 minutes (ideally overnight) of powered warm-up before the first weighing.
Calibration and verification
Run internal calibration once warmed up, then verify externally with an ASTM Class 1 or OIML E2 weight. Repeatability should be checked with ten replicate weighings of the same mass — the standard deviation must stay within the balance's stated repeatability. USP <41> users must additionally confirm the minimum sample weight.
Error codes and symptoms
| Symptom | Cause and remedy |
|---|---|
| Unstable / flashing reading | Air movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading. |
| Over-capacity indication (E, EEEE, or ---- ) | Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero. |
| Will not zero at power-up | Something is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle. |
| Calibration fails or rejects the weight | Wrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up. |
| Drifting reading over minutes | Thermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders. |
| Reading creeps after loading | Sample is hygroscopic or electrostatically charged, or the door was closed too quickly. Use a closed vessel and an ioniser. |
Care and re-verification
Handle weights with forceps only, keep the draft shield closed between weighings, and never brush the pan with a hand — use a soft brush.
Need the printed PDF? The official Sartorius Lab Instruments manual library is at Sartorius Lab Instruments documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.
Customer reviews for BYK-Gardner 1636
No reviews yet. Be the first to review this product.