CAS CL5500 Pole Electronic Price Computing Scale with Dual LCD Display, Ethernet
$2345.00
Price-computing and label-printing retail scales must be NTEP-approved and legal for trade when used to sell by weight. PLU count, label format and printer supplies are the practical considerations.
At a glance
- Model: CL5500
- Brand: CAS
- Category: Retail Scale
Not sure this is the right model for your application? Our technicians match scales to real-world jobs every day and will confirm capacity, readability and legal-for-trade requirements before you order.
Why buy from EK1200i.com
- Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
- Free fast shipping within the mainland USA
- In-house NIST-traceable calibration available before shipment on request
- Live phone and email support from working scale technicians in Cypress, Texas
- Full-service calibration and repair lab for the life of your scale
Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.
Need bulk pricing? Contact us for special pricing on volume orders.
Specifications
- Manufacturer
- CAS
- Model
- CL5500
- Instrument class
- Price-computing retail scale
- SKU / Part number
- CAS-CL5500-2
- Price (USD)
- $2345.00
- Availability
- In stock — ships from the USA
- Shipping
- Free ground shipping, mainland USA
- Warranty
- Full manufacturer warranty, registered to the buyer
- Calibration
- NIST-traceable, performed in Cypress, TX
What is a price-computing retail scale, and how does this one work?
A price-computing scale multiplies net weight by a unit price to display the total charge, and is used at any counter that sells goods by weight. In the United States, this class of scale must be NTEP-certified and sealed by the state or county weights-and-measures office before it may be used in commerce.
A single-point load cell measures net weight; firmware applies the tare, multiplies by the entered unit price, and rounds the total to the nearest cent using the rounding rules in NIST Handbook 44. Certified models include a dual display so the customer can independently see weight, unit price, and total — a legal requirement, not a convenience feature.
Where the CL5500 is used
- •Delis, butchers, cheese counters, and bakeries
- •Produce markets and farm stands
- •Candy, coffee, and bulk-bin retail
- •Cannabis dispensaries (where a certified scale is mandated)
- •Fish markets and seafood counters
Getting accurate results
- •Always tare wrapping, film, and containers. Charging the customer for packaging weight is a compliance violation in every US jurisdiction.
- •Have the scale inspected and sealed on installation and re-verified on the schedule your local jurisdiction requires — typically annually.
- •Keep the platter level and clean; a tilted counter changes readings on a Class III device by more than the legal tolerance.
- •Verify with a known test weight at open of business as a quick self-check.
Frequently asked questions about the CL5500
What are the capacity and readability of the CL5500?
Capacity and readability for the CL5500 are listed in the specification table above.
What test weight is needed to calibrate the CL5500?
A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.
How often should the CL5500 be calibrated?
Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.
Is the CL5500 legal for trade?
A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.
What is the difference between readability and accuracy?
Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.
How fast does the CL5500 ship, and can it be repaired?
In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.
CL5500 manual summary and troubleshooting
Unpacking and installation
Fit the platter and customer display, level the unit, and load label or receipt stock where fitted. The scale must be sealed by the state weights-and-measures authority before commercial use.
Calibration and verification
Legal-for-trade calibration and sealing is performed by a licensed service agency; do not break the seal. Verify daily with a check weight and record the result.
Error codes and symptoms
| Symptom | Cause and remedy |
|---|---|
| Total price wrong | Unit price entered per pound instead of per kilogram, or vice versa. Confirm the pricing unit. |
| Printer feeds blank labels | Label stock loaded past the sensor or wrong label format selected. |
| Unstable / flashing reading | Air movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading. |
| Over-capacity indication (E, EEEE, or ---- ) | Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero. |
Care and re-verification
Keep the platter and label path clean, use manufacturer label stock, and renew the state seal on schedule.
Need the printed PDF? The official CAS Corporation manual library is at CAS Corporation documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.
Customer reviews for CL5500
No reviews yet. Be the first to review this product.