Back to all A&D scales
    Compression Scale 5000 x 1 lb with Low profile Load cell IDS-672-5K, Portable Display and Power cord

    Compression Scale 5000 x 1 lb with Low profile Load cell IDS-672-5K, Portable Display and Power cord

    $539.00

    Item specifics

    Compression Set scale 5000 x 1 lb accuracy Compression Load Cell Pancake 5000 Lb

    OP-901A/ OP-901B indicator

    Low Profile Disk compression Load cell 10k

    Digital LED indicator OP-901A/ or LCD OP-901B with rechargeable battery and power cord.
    5000 LB Load cell with Certificate of load cell

    Load cells are the sensing element in a weighing system. Match capacity, output (mV/V), excitation voltage, cable length, environmental rating and mounting style to your indicator and structure.

    At a glance

    • Model: IDS-672-5K
    • Brand: MNM Scales
    • Category: Load Cell

    Not sure this is the right model for your application? Our technicians match scales to real-world jobs every day and will confirm capacity, readability and legal-for-trade requirements before you order.

    Why buy from EK1200i.com

    • Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
    • Free fast shipping within the mainland USA
    • In-house NIST-traceable calibration available before shipment on request
    • Live phone and email support from working scale technicians in Cypress, Texas
    • Full-service calibration and repair lab for the life of your scale

    Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.

    Request Quote
    Authorized A&D Dealer
    Free Mainland US Shipping
    Expert Support

    Need bulk pricing? Contact us for special pricing on volume orders.

    Specifications

    Manufacturer
    MNM Scales
    Model
    IDS-672-5K
    Instrument class
    Floor scale
    Capacity
    1 lb
    SKU / Part number
    MNMSC-IDS-672-5K-1LB-1
    Price (USD)
    $539.00
    Availability
    In stock — ships from the USA
    Shipping
    Free ground shipping, mainland USA
    Warranty
    Full manufacturer warranty, registered to the buyer
    Calibration
    NIST-traceable, performed in Cypress, TX

    Capacity in other units

    Grams (g)
    453.592
    Kilograms (kg)
    0.4536
    Pounds (lb)
    1
    Ounces (oz)
    16
    Troy ounces (ozt)
    14.583
    Carats (ct)
    2,268

    What is a floor scale, and how does this one work?

    A floor scale is a low-profile, high-capacity platform installed at or near ground level for pallets, drums, and carts. The IDS-672-5K is rated to 1 lb. A typical unit uses four shear-beam load cells at the platform corners feeding a summing junction box and a separate indicator.

    Each of the four shear-beam cells carries roughly one quarter of the load. Their millivolt outputs are combined in a junction box, where trim potentiometers or digital corner adjustment equalise the cells so the reading is the same wherever the load sits on the deck. Because total capacity is divided across four cells, a 5,000 lb floor scale is built from four 2,500 lb cells to allow for uneven and dynamic loading.

    Where the IDS-672-5K is used

    • •Pallet and freight weighing in warehousing and 3PL
    • •Drum and tote filling in chemical processing
    • •Scrap, recycling, and waste-stream measurement
    • •Manufacturing WIP and raw-material receiving
    • •Livestock and agricultural bulk handling

    Getting accurate results

    • •Anchor or shim the scale so all four feet carry load; an unloaded corner destroys accuracy and overloads the other three cells.
    • •Perform a corner (section) test at commissioning and annually: a test load at each corner should agree within one division.
    • •Never weld on or near the platform without disconnecting the cells — welding current through a load cell destroys it.
    • •Keep the pit or under-deck area free of debris; anything touching the deck bypasses the cells.

    Frequently asked questions about the IDS-672-5K

    What are the capacity and readability of the IDS-672-5K?

    The IDS-672-5K is rated to 1 lb. Subtract the mass of any container or fixture from capacity to get your usable weighing range, because tare does not add capacity back.

    What test weight is needed to calibrate the IDS-672-5K?

    A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.

    How often should the IDS-672-5K be calibrated?

    Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.

    Is the IDS-672-5K legal for trade?

    A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.

    What is the difference between readability and accuracy?

    Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.

    How fast does the IDS-672-5K ship, and can it be repaired?

    In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.

    IDS-672-5K manual summary and troubleshooting

    Unpacking and installation

    Set the deck on a flat, cured concrete floor and shim each foot until all four load cells carry load. Route the summing-junction cable clear of forklift traffic and secure the indicator at eye height.

    Calibration and verification

    After levelling, perform a corner (shift) test: place a known weight of roughly one third of capacity over each load cell in turn. Readings must agree within the permitted error before span calibration is trusted.

    Error codes and symptoms

    SymptomCause and remedy
    One corner reads lowFoot not carrying load or a failed load cell. Re-shim, then measure cell output at the junction box.
    Reading jumps with forklift trafficCable damage or a loose junction-box connection. Inspect and re-terminate.
    Over-capacity indication (E, EEEE, or ---- )Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero.
    Will not zero at power-upSomething is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle.

    Care and re-verification

    Keep debris out from under the deck, wash down only to the stated IP rating, and re-run the corner test after any move.

    Need the printed PDF? Call 832-290-3120 and we will email the exact manual revision for your serial number. See also the manual & documentation library.

    Customer reviews for IDS-672-5K