    General purpose scale. Compact and durable.

    Exclusive “Quad-Spring” Shockproof Design

    The PC-400 includes our field-proven exclusive “Quad-Spring” base design that virtually eliminates damage from shock and overload.

    AC Power or Rechargeable Battery

    The choice is yours. Use the included AC plug-in adapter or the internal rechargeable battery for total portability. Recharge the battery in less than four hours with the AC adapter; you can even use the PC-400 portion control while it’s recharging.

    Stainless Steel Construction

    The case and removable platter are constructed with food-grade 304 stainless steel. Designed to be wipedown-safe PC-400 cleans easily and quickly.

    Specifications

    Warranty: Scale: One Year
    Battery: 90 Days
    Power: Internal rechargeable battery and wall mounted AC transformer standard
    Serial Interface: Bi-directional RS-232
    Controls: On/Off, Zero, and Units
    Temperature Range: 14° to 104° F (-10° to +40° C)
    System Linearity: 0.01% full scale
    Dimensions

    Capacity:

    Overall: 8.75″ L x 6.5″ W x 2″
    : Platter: 6.5″ x 6.5″2 x 0.0002 lb
    1000 x 0.1 g
    35 x 0.005 oz

    Why buy from EK1200i.com

    • Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
    • Free fast shipping within the mainland USA
    • In-house NIST-traceable calibration available before shipment on request
    • Live phone and email support from working scale technicians in Cypress, Texas
    • Full-service calibration and repair lab for the life of your scale

    Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.

    Request Quote
    Authorized A&D Dealer
    Free Mainland US Shipping
    Expert Support

    Need bulk pricing? Contact us for special pricing on volume orders.

    Specifications

    Manufacturer
    Doran
    Model
    PC400-02LFT
    Instrument class
    Weighing scale
    Capacity
    0.002 lb
    SKU / Part number
    DORAN-PC400-02LFT-0.002LB-0002
    Price (USD)
    $359.00
    Availability
    In stock — ships from the USA
    Shipping
    Free ground shipping, mainland USA
    Warranty
    Full manufacturer warranty, registered to the buyer
    Calibration
    NIST-traceable, performed in Cypress, TX

    Capacity in other units

    Grams (g)
    0.907
    Kilograms (kg)
    0.0009
    Pounds (lb)
    0.002
    Ounces (oz)
    0.03
    Troy ounces (ozt)
    0.029
    Carats (ct)
    4.5

    What is a weighing scale, and how does this one work?

    PC400-02LFT is a weighing instrument for professional use. It is rated to 0.002 lb. Choosing a scale comes down to three numbers — capacity, readability, and division count — plus the environment it must survive in.

    Nearly all modern scales convert force into an electrical signal. Industrial and bench models use strain-gauge load cells, in which bonded foil gauges change resistance as a machined steel or aluminium element deforms under load. Laboratory balances use electromagnetic force restoration, which measures the current needed to hold the pan at a fixed null position and so avoids relying on mechanical deformation at all.

    Where the PC400-02LFT is used

    • •Laboratory and quality-control measurement
    • •Manufacturing, batching, and inventory control
    • •Shipping, receiving, and logistics
    • •Retail and food service
    • •Field and service work

    Getting accurate results

    • •Calibrate on installation, after any move, and on a documented interval thereafter.
    • •Use a certified test weight whose tolerance is no more than one third of the scale's smallest division.
    • •Keep the instrument level, clean, and away from airflow and vibration.
    • •Re-zero before each weighing rather than relying on a stale tare.
    • •Readability (also written as d, or the display division) is the smallest change in mass the display can show. It is not the same as accuracy: a balance reading to 0.01 g may still carry a linearity error of ±0.02 g. Accuracy is bounded by readability, repeatability (standard deviation of repeated loads), and linearity combined.

    Frequently asked questions about the PC400-02LFT

    What are the capacity and readability of the PC400-02LFT?

    The PC400-02LFT is rated to 0.002 lb. Subtract the mass of any container or fixture from capacity to get your usable weighing range, because tare does not add capacity back.

    What test weight is needed to calibrate the PC400-02LFT?

    A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.

    How often should the PC400-02LFT be calibrated?

    Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.

    Is the PC400-02LFT legal for trade?

    A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.

    What is the difference between readability and accuracy?

    Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.

    How fast does the PC400-02LFT ship, and can it be repaired?

    In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.

    PC400-02LFT manual summary and troubleshooting

    Unpacking and installation

    Unpack on the bench where the instrument will live, fit the platter or pan, and connect the supplied adapter. Level the instrument using the feet until the bubble is centred, then let it power up and warm through before the first weighing.

    Calibration and verification

    Run the span calibration routine with a certified test weight at or near full capacity, then verify with a second weight near one third of capacity. Record both readings and the date in a calibration log.

    Error codes and symptoms

    SymptomCause and remedy
    Unstable / flashing readingAir movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading.
    Over-capacity indication (E, EEEE, or ---- )Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero.
    Will not zero at power-upSomething is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle.
    Calibration fails or rejects the weightWrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up.
    Drifting reading over minutesThermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders.

    Care and re-verification

    Keep the platter clean and dry, avoid shock loading, store certified test weights in their case and re-verify after any move.

    Need the printed PDF? The official Doran Scales, Inc. manual library is at Doran Scales, Inc. documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.