Intelligent VGW 10001 Lab Balance 10,000 x 0.1g Weighing Scale
$453.00
On SaleMSRP $545.00 — you save $92.00 (17% off)
Intell-Lab™Top Loading Balance VGW-10001
Intelligent Weighing VGW check weighing scales provide an accurate and affordable solution to your check weighing needs. The VGW features a Hi-Lo-Go check weighing system with an audible warning when a sample is out of range. The 3-color (red, yellow, green) LCD display provides a visual indication of over or under to make the check weighing process quicker.
Features
- 10,000 x 0.1 g capacity
- Hi-Lo-Go Check Weighing w/ Audible Warning
- Rechargeable Battery: up to 200 hrs.
- Bi-Directional RS232 Interface
- 3 Color LCD Display
- Units: kg, g, lb
Functions
- Check Weighing
- General weighing
- Counting
- Accumulation
Capacity:10, 000 gReadability:0.1 gLinearity:± 0.3 gRepeatability:± 0.2 gWeighing Units:kg, g, lbConstruction:ABS Plastic housing, stainless steel insertCalibration:ExternalCommunication:RS 232 Interface, Selectable Transmission ModesDisplay Type:3 Color LCD DisplayOverall Dimensions:9.4 x 11.2 x 4.1 in / 240 x 285 x 105 mmPan Size:9.24 x 9.86 in. / 230 x 250 mmWeight:5.0 lb / 2.2 kgPower:Internal Rechargeable Battery, AC/DC AdaptorBrand:Intelligent Weighing TechnologyModel:VGW 10001
Why buy from EK1200i.com
- Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
- Free fast shipping within the mainland USA
- In-house NIST-traceable calibration available before shipment on request
- Live phone and email support from working scale technicians in Cypress, Texas
- Full-service calibration and repair lab for the life of your scale
Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.
Need bulk pricing? Contact us for special pricing on volume orders.
Specifications
- Manufacturer
- MNM Scales
- Model
- VGW-10001
- Instrument class
- Precision balance
- Capacity
- 0.1 g
- SKU / Part number
- MNMSC-VGW10001-0.1G-01
- Price (USD)
- $453.00
- Availability
- In stock — ships from the USA
- Shipping
- Free ground shipping, mainland USA
- Warranty
- Full manufacturer warranty, registered to the buyer
- Calibration
- NIST-traceable, performed in Cypress, TX
Capacity in other units
- Grams (g)
- 0.1
- Kilograms (kg)
- 0.0001
- Pounds (lb)
- 0
- Ounces (oz)
- 0
- Troy ounces (ozt)
- 0.003
- Carats (ct)
- 0.5
What is a precision balance, and how does this one work?
A precision balance (also called a top-loading balance) measures mass at readabilities between 1 g and 0.001 g, with a larger capacity and faster stabilisation than an analytical balance and usually no full draft shield. The VGW-10001 offers 0.1 g capacity at readability. It is the workhorse instrument for formulation, QC sampling, education, and any task where analytical-grade resolution is unnecessary but 0.1 g bathroom-scale accuracy is not enough.
Precision balances above about 0.01 g resolution may use either electromagnetic force restoration or a high-quality single-point strain-gauge load cell. A single-point cell is machined from one aluminium block with strain gauges bonded to flexure sections; it is corner-load compensated so a sample placed off-centre on the pan reads the same as one placed in the middle. EMFR models cost more but drift less with temperature and settle faster.
Where the VGW-10001 is used
- •Formulation and batching in food, cosmetics, and chemical production
- •Incoming QC sample weighing and yield checks
- •Education: physics, chemistry, and biology teaching labs
- •Density determination with a below-balance hook or density kit
- •Coating, plating, and filter-weight differential measurement
Getting accurate results
- •Calibrate with a weight close to full capacity — span error is proportional to load, so a 100 g weight cannot validate a 3200 g range.
- •Use an ASTM Class 1 or Class 2 test weight for balances at 0.001–0.01 g. Handbook 105-1 guidance is that the weight's tolerance should not exceed 1/3 of the scale's smallest division.
- •Keep the balance out of HVAC airflow and off shared benches with centrifuges or stirrers.
- •Re-zero before every weighing rather than trusting an old tare; drift over hours is normal and expected.
- •Readability (also written as d, or the display division) is the smallest change in mass the display can show. It is not the same as accuracy: a balance reading to 0.01 g may still carry a linearity error of ±0.02 g. Accuracy is bounded by readability, repeatability (standard deviation of repeated loads), and linearity combined.
Frequently asked questions about the VGW-10001
What are the capacity and readability of the VGW-10001?
The VGW-10001 is rated to 0.1 g. Subtract the mass of any container or fixture from capacity to get your usable weighing range, because tare does not add capacity back.
What test weight is needed to calibrate the VGW-10001?
A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.
How often should the VGW-10001 be calibrated?
Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.
Is the VGW-10001 legal for trade?
A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.
What is the difference between readability and accuracy?
Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.
How fast does the VGW-10001 ship, and can it be repaired?
In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.
VGW-10001 manual summary and troubleshooting
Unpacking and installation
Unpack on the bench where the instrument will live, fit the platter or pan, and connect the supplied adapter. Level the instrument using the feet until the bubble is centred, then let it power up and warm through before the first weighing.
Calibration and verification
Run the span calibration routine with a certified test weight at or near full capacity, then verify with a second weight near one third of capacity. Record both readings and the date in a calibration log.
Error codes and symptoms
| Symptom | Cause and remedy |
|---|---|
| Unstable / flashing reading | Air movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading. |
| Over-capacity indication (E, EEEE, or ---- ) | Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero. |
| Will not zero at power-up | Something is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle. |
| Calibration fails or rejects the weight | Wrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up. |
| Drifting reading over minutes | Thermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders. |
Care and re-verification
Keep the platter clean and dry, avoid shock loading, store certified test weights in their case and re-verify after any move.
Need the printed PDF? Call 832-290-3120 and we will email the exact manual revision for your serial number. See also the manual & documentation library.
Customer reviews for VGW-10001
No reviews yet. Be the first to review this product.