Back to all A&D scales
    MNM Scales, GX-1SH-2.5K Waterproof Stainless Steel Shear Beam Load Cell with

    MNM Scales, GX-1SH-2.5K Waterproof Stainless Steel Shear Beam Load Cell with

    $129.00

    Product Features Stainless steel, sealed good for waterproof floor scales 2500 lb load cell one scale foot, one spacer

    Load cells are the sensing element in a weighing system. Match capacity, output (mV/V), excitation voltage, cable length, environmental rating and mounting style to your indicator and structure.

    At a glance

    • Model: GX-1SH-2
    • Brand: MNM Scales
    • Category: Load Cell

    Not sure this is the right model for your application? Our technicians match scales to real-world jobs every day and will confirm capacity, readability and legal-for-trade requirements before you order.

    Why buy from EK1200i.com

    • Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
    • Free fast shipping within the mainland USA
    • In-house NIST-traceable calibration available before shipment on request
    • Live phone and email support from working scale technicians in Cypress, Texas
    • Full-service calibration and repair lab for the life of your scale

    Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.

    Request Quote
    Authorized A&D Dealer
    Free Mainland US Shipping
    Expert Support

    Need bulk pricing? Contact us for special pricing on volume orders.

    Specifications

    Manufacturer
    MNM Scales
    Model
    MNM Scales,
    Instrument class
    Scale accessory
    SKU / Part number
    MNMSC-GX-1SH-2
    Price (USD)
    $129.00
    Availability
    In stock — ships from the USA
    Shipping
    Free ground shipping, mainland USA
    Warranty
    Full manufacturer warranty, registered to the buyer
    Calibration
    NIST-traceable, performed in Cypress, TX

    What is a scale accessory, and how does this one work?

    MNM Scales, is a scale accessory or replacement part. Genuine manufacturer parts matter more on weighing equipment than on most machinery, because a substituted pan, foot, or draft shield changes the mechanical load path and therefore the calibration.

    Weighing accessories fall into three groups: mechanical parts that contact the load path (pans, hooks, draft shields, feet), interface hardware (RS-232 and USB adapters, printers, remote displays), and consumables (paper rolls, dust covers, batteries). Anything in the first group should be replaced with an OEM part and followed by recalibration.

    Where the MNM Scales, is used

    • •Preventive maintenance and spares stocking
    • •Adding data output to an existing scale
    • •Restoring a scale after damage rather than replacing it

    Getting accurate results

    • •Record the part number from the scale's rating plate rather than from the model name alone; sub-variants are common.
    • •Keep a spare dust cover and paper roll on hand for production scales; downtime usually comes from consumables.
    • •Verify calibration after any part replacement and keep the record.

    Frequently asked questions about the MNM Scales,

    What are the capacity and readability of the MNM Scales,?

    Capacity and readability for the MNM Scales, are listed in the specification table above.

    What test weight is needed to calibrate the MNM Scales,?

    A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.

    How often should the MNM Scales, be calibrated?

    Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.

    Is the MNM Scales, legal for trade?

    A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.

    What is the difference between readability and accuracy?

    Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.

    How fast does the MNM Scales, ship, and can it be repaired?

    In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.

    MNM Scales, manual summary and troubleshooting

    Unpacking and installation

    Unpack on the bench where the instrument will live, fit the platter or pan, and connect the supplied adapter. Level the instrument using the feet until the bubble is centred, then let it power up and warm through before the first weighing.

    Calibration and verification

    Run the span calibration routine with a certified test weight at or near full capacity, then verify with a second weight near one third of capacity. Record both readings and the date in a calibration log.

    Error codes and symptoms

    SymptomCause and remedy
    Unstable / flashing readingAir movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading.
    Over-capacity indication (E, EEEE, or ---- )Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero.
    Will not zero at power-upSomething is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle.
    Calibration fails or rejects the weightWrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up.
    Drifting reading over minutesThermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders.

    Care and re-verification

    Keep the platter clean and dry, avoid shock loading, store certified test weights in their case and re-verify after any move.

    Need the printed PDF? Call 832-290-3120 and we will email the exact manual revision for your serial number. See also the manual & documentation library.

    Customer reviews for MNM Scales,

    No reviews yet. Be the first to review this product.