Ohaus EX10202N Explorer Toploading Balance, 10200g x 0.01g with NTEP Certified
$3868.00
On SaleMSRP $5415.00 — you save $1547.00 (29% off)
Capacity 10200 g × readability 0.01 g.
Ohaus EX10202N – Legal for Trade Scale
Completely re-imagined from the ground up, the OHAUS Explorer® rises to a whole new level. Explorer delivers accurate results within seconds, improving operator efficiency, productivity and throughput, with a stabilization time up to 50% faster. Featuring SmarText™ 2.0, OHAUS’ easy-to-use graphical software offering 14 applications, QWERTY and numeric keypads, and below-minimum weight indication. Explorer’s draftshield provides ample access and visibility to the weighing chamber and features antistatic coated glass. Explorer features four touchless sensors for hands-free operation of print, calibration, tare, and other selectable functions. AutoCal™ ensures performance and assists with routine maintenance by automatically calibrating the balance daily. Explorer is the industry’s most easy-to-use balance, featuring leveling assistance and instructional messaging for quick out-of-the-box setup and use. Explorer’s modular design features a color touch display that can be separated from the weighing base.
Special Features:
- Ultra-Fast Stabilization Time
- Four Touchless Sensors
- Touch Color VGA Display with Icons
- Display can be separated from weighing base
- Illuminated Up-Front Level Indicator
- Fully Automatic Internal Calibration
- Multiple Weighing Units (g,mg,kg,oz,lb,ozt,ct,dwt,GN, Newton, Momme, Mesghal, Tael, Tical, Tola, 3 custom units)
- Superior Overload and Underload Protection
- Multiple Application Modes
- Percent Weighing – Measure the weight of a sample displayed as a % of a pre-established reference weight.
- Dynamic (Animal) Weighing – Weigh an unstable load. Balance takes an avg. of weights over a time period.
- Totalization – Measure cumulative weight of multiple items. Cumulative total may exceed balance capacity.
- Differential Weighing – Store sample weights and calculate the difference between initial weights and final weights.
- Peak Hold – Capture and store hightest weight in a series. Both stable and unstable weights are captured.
- Parts Counting – Count samples of uniform weight. Choose std. Counting, check counting or fill counting.
- Pipette Adjustment – Check pipette values by weight analysis, with built-in water density table.
- Check Weighing – Compare the weight of a sample against target limits. Choose from std, nominal-weight or nominal-percent.
- Filling – Fill a container to a target weight. Progress bar displays filling status.
- Formulation – For compounding and recipe making. The number of components can be from two to 99.
- Density Determination – Determine density of solids more dense than water, solids less dense than water, liquids or porous material.
- Ingredient Costing – Determine cost of formula or recipe based on known cost/quantity of components or ingredients.
- SQC – Monitor and/or control processes to eliminate under and over filling.
- Library Function to store and recall customized applications
- Alternate RS232 command feature adapts the balance to existing data acquisition software
- Data Transfer Function Outputs Data Directly to Microsoft Excel
- Standard USB & RS232 Ports
- Optional 2nd RS232 and Ethernet
- Security Bracket
- Intuitive Operating System
- Power Auto-Off
- Menu Lock Switch
- QuadraStance design w four adj. thumbwheels for superior stability
- NTEP Certified Legal for Trade
- 2 year warranty
| Ohaus – EX10202N | |
|---|---|
| Capacity | 10200g |
| Readability | 0.01g (0.1g NTEP) |
| Pan Size | 7.5 x 7.9 in / 190 x 200 mm |
| Repeatability | ±0.01g |
| Linearity | ±0.02g |
| Stabilization Time | ≤1 sec |
| Calibration | AutoCal™ on Δ1.5°C temperature change, 11 hours, and external calibration |
| Weighing Units | Gram, Milligram, Kilogram, Carat, Ounce, Ounce Troy, Pound, Pennyweight, Grain, Newton, Momme, Mesghal, Hong Kong Tael, Singapore Tael, Taiwan Tael, Tical, Tola, Baht, 3 Custom Units |
| Application Modes | Weighing, Percent Weighing, Parts Counting, Check Weighing, Dynamic/Animal Weighing, Filling, Totalization, Formulation, Differential Weighing, Density Determination, Peak Hold, Ingredient Costing, Pipette Adjustment, SQC |
| Communication | RS232, USB |
| Display Type | Full-color VGA graphic display, 4-wire resistive touch screen |
| Display Size | 5.7 in / 145 mm (diagonal) |
| Display Housing Dimensions (WxHxD) | 7.7 x 3.5 x 6.0 in / 195 x 90 x 154 mm |
| Base Housing Dimensions (WxHxD) | 9.1 x 3.9 x 15.5 in / 230 x 98 x 393 mm |
| Pan Size | 7.5 x 7.9 in / 190 x 200 mm |
| Leveling Adjustment | Front-mounted level bubble with illumination / QuadraStance adjustable leveling feet |
| Tare Range | Full capacity by subtraction |
| Operating Temperature Range | 50°F (10°C) to 86°F (30°C) |
| Operating Humidity Range | 15% to 80% at 87.8°F (31°C) |
| Storage Conditions | -14°F (-10°C) to 140°F (60°C) at 10% to 90% relative humidity, non-condensing |
| Power Requirements | AC adapter input: 100-240 VAC 0.6A 50-60 Hz |
| Shipping Dimensions | 21 x 15 x 12 in / 55 x 38.5 x 29.1 cm |
| Net Weight | 11 lb / 5 kg |
| Shipping Weight | 16.3 lb / 7.4 kg |
Why buy from EK1200i.com
- Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
- Free fast shipping within the mainland USA
- In-house NIST-traceable calibration available before shipment on request
- Live phone and email support from working scale technicians in Cypress, Texas
- Full-service calibration and repair lab for the life of your scale
Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.
Need bulk pricing? Contact us for special pricing on volume orders.
Specifications
- Manufacturer
- Ohaus
- Model
- EX10202N
- Instrument class
- Precision balance
- Capacity
- 10,200 g
- Readability (d)
- 0.01 g
- Display divisions
- 1,020,000
- SKU / Part number
- OHAUS-EX10202N-10200G-10202
- Price (USD)
- $3868.00
- Availability
- In stock — ships from the USA
- Shipping
- Free ground shipping, mainland USA
- Warranty
- Full manufacturer warranty, registered to the buyer
- Calibration
- NIST-traceable, performed in Cypress, TX
Capacity in other units
- Grams (g)
- 10,200
- Kilograms (kg)
- 10.2
- Pounds (lb)
- 22.487
- Ounces (oz)
- 359.79
- Troy ounces (ozt)
- 327.938
- Carats (ct)
- 51,000
What is a precision balance, and how does this one work?
A precision balance (also called a top-loading balance) measures mass at readabilities between 1 g and 0.001 g, with a larger capacity and faster stabilisation than an analytical balance and usually no full draft shield. The EX10202N offers 10,200 g capacity at 0.01 g readability — 1,020,000 display divisions. It is the workhorse instrument for formulation, QC sampling, education, and any task where analytical-grade resolution is unnecessary but 0.1 g bathroom-scale accuracy is not enough.
Precision balances above about 0.01 g resolution may use either electromagnetic force restoration or a high-quality single-point strain-gauge load cell. A single-point cell is machined from one aluminium block with strain gauges bonded to flexure sections; it is corner-load compensated so a sample placed off-centre on the pan reads the same as one placed in the middle. EMFR models cost more but drift less with temperature and settle faster.
Where the EX10202N is used
- •Formulation and batching in food, cosmetics, and chemical production
- •Incoming QC sample weighing and yield checks
- •Education: physics, chemistry, and biology teaching labs
- •Density determination with a below-balance hook or density kit
- •Coating, plating, and filter-weight differential measurement
Getting accurate results
- •Calibrate with a weight close to full capacity — span error is proportional to load, so a 100 g weight cannot validate a 3200 g range.
- •Use an ASTM Class 1 or Class 2 test weight for balances at 0.001–0.01 g. Handbook 105-1 guidance is that the weight's tolerance should not exceed 1/3 of the scale's smallest division.
- •Keep the balance out of HVAC airflow and off shared benches with centrifuges or stirrers.
- •Re-zero before every weighing rather than trusting an old tare; drift over hours is normal and expected.
- •Readability (also written as d, or the display division) is the smallest change in mass the display can show. It is not the same as accuracy: a balance reading to 0.01 g may still carry a linearity error of ±0.02 g. Accuracy is bounded by readability, repeatability (standard deviation of repeated loads), and linearity combined.
Frequently asked questions about the EX10202N
What are the capacity and readability of the EX10202N?
The EX10202N is rated to 10,200 g with 0.01 g readability, which is 1,020,000 display divisions across the range. Subtract the mass of any container or fixture from capacity to get your usable weighing range, because tare does not add capacity back.
What test weight is needed to calibrate the EX10202N?
A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division (0.01 g here), per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.
How often should the EX10202N be calibrated?
Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.
Is the EX10202N legal for trade?
A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.
What is the difference between readability and accuracy?
Readability is the smallest increment the display can show — 0.01 g on the EX10202N. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.
How fast does the EX10202N ship, and can it be repaired?
In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.
EX10202N manual summary and troubleshooting
Unpacking and installation
Unpack on the bench where the instrument will live, fit the platter or pan, and connect the supplied adapter. Level the instrument using the feet until the bubble is centred, then let it power up and warm through before the first weighing.
Calibration and verification
Run the span calibration routine with a certified test weight at or near full capacity, then verify with a second weight near one third of capacity. Record both readings and the date in a calibration log.
Error codes and symptoms
| Symptom | Cause and remedy |
|---|---|
| Unstable / flashing reading | Air movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading. |
| Over-capacity indication (E, EEEE, or ---- ) | Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero. |
| Will not zero at power-up | Something is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle. |
| Calibration fails or rejects the weight | Wrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up. |
| Drifting reading over minutes | Thermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders. |
Care and re-verification
Keep the platter clean and dry, avoid shock loading, store certified test weights in their case and re-verify after any move.
Need the printed PDF? The official OHAUS Corporation manual library is at OHAUS Corporation documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.
Customer reviews for EX10202N
No reviews yet. Be the first to review this product.