Ohaus Pioneer PX225D Semi Micro Balance 220 gram Internal Calibration
$4750.00
On SaleMSRP $6080.00 — you save $1330.00 (22% off)
Ohaus PX225D – Semi-Micro Balance
The Ohaus PX225D semi-micro balance has a capacity of 82 / 220 grams with a readability of 0.01 / 0.1 milligram and comes with a 3.15″ (80mm) diameter weighing pan and features automatic internal calibration. The Ohaus Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The Pioneer PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS-232 connectivity for easy communication.
Special Features:
- 2 Line Display A brightly lit dual line display shows the weight in an easy-to-read manner, while a dot-matrix second line provides additional information or guidance prompts to the user.
- Durable Construction Featuring a cast metal lower housing, metal sub-pan, stainless steel weighing pan and removable draftshield or side doors, the Pioneer is durably constructed for long-term use, and suitable for a variety of applications.
- Communication Ports Standard RS-232 and USB device ports allow for easy connectivity to printers and other peripherals, allowing convenient capture of results. OHAUS’ free data collection tool (SPDC) provides a simple solution to import this data directly in formats such as Excel, Access, .txt, .csv etc..
- Static Removal Bar A static removal bar along the top of the draftshield provides a convenient grounding location, allowing the user to discharge any static charge that may have accumulated prior to handling samples and weighing. This helps compliance with good weighing practices, while improving the stability and accuracy of results.
- 2 Year Warranty
| Ohaus – PX225D | |
|---|---|
| Capacity | 82 / 220 g |
| Readability | 0.01 / 0.1 mg |
| Pan Size | Ø3.15″ (80mm) |
| Repeatability (STDEV) (g) | 0.03 mg / 0.1 mg (dual range) |
| Linearity (g) | ±0.1 mg |
| Stabilization Time (s) | 10 |
| Units | Milligram, Gram, Kilogram, Ounce, Pound, Carat, Pennyweight, Ounce Troy, Grain, Newton Hong Kong Tael, Singapore Tael, Taiwan Tael, Momme, Tical (MM), Mesghal, Tola (India), 1 Custom unit |
| Applications | Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination |
| Pan Size | Ø3.15 inches / 80 mm |
| Calibration | Automatic Internal Calibration |
| Interfaces | RS-232 and USB |
| Draftshield Dimensions | 6.8 x 5.2 x 8.1 inches / 172 x 131 x 205 mm |
| Power Supply | Power Input: 100 – 240V ~ 200mA 50/60Hz, 12 18VA Power Output: 12VDC, 0.5A |
| Overall Dimensions | 8.2 x 12.6 x 13.3 inches / 20.8 x 32.0 x 33.9 cm |
| Operating Conditions | 50°F to 86°F / 10°C to 30°C |
| Storage Conditions | 14°F to 140°F / -10°C to 60°C at 10% to 90% relative humidity, non-condensing |
| Net Weight | 10 lbs / 4.5 kg |
| Shipping Weight | 15.4 lbs / 7 kg |
| Shipping Dimensions | 20 x 15 x 12 inches / 55 x 38.5 x 29.1 cm |
Why buy from EK1200i.com
- Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
- Free fast shipping within the mainland USA
- In-house NIST-traceable calibration available before shipment on request
- Live phone and email support from working scale technicians in Cypress, Texas
- Full-service calibration and repair lab for the life of your scale
Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.
Need bulk pricing? Contact us for special pricing on volume orders.
Specifications
- Manufacturer
- Ohaus
- Model
- PX225D
- Instrument class
- Analytical balance
- SKU / Part number
- OHAUS-PX225D-225
- Price (USD)
- $4750.00
- Availability
- In stock — ships from the USA
- Shipping
- Free ground shipping, mainland USA
- Warranty
- Full manufacturer warranty, registered to the buyer
- Calibration
- NIST-traceable, performed in Cypress, TX
What is a analytical balance, and how does this one work?
An analytical balance is a laboratory instrument that measures mass to 0.1 mg (0.0001 g) or finer inside an enclosed draft shield. At this resolution, air currents, temperature gradients, static charge, and building vibration all become measurable sources of error, which is why analytical balances use a windshield, a level indicator, and often internal motorised calibration.
Analytical balances use electromagnetic force restoration (EMFR), not a strain-gauge load cell. A coil sits in a permanent magnetic field; when mass is applied, a position sensor detects the deflection and the servo loop increases coil current until the pan returns to its null position. The current required is directly proportional to the applied force, so the reading is derived from a measured electrical quantity rather than from mechanical deformation. This is what makes 0.1 mg resolution and long-term stability possible.
Where the PX225D is used
- •Analytical chemistry: standard and reagent preparation, gravimetric analysis
- •Pharmaceutical QC and compounding under USP 41/1251
- •Materials research, catalyst and polymer sample preparation
- •Environmental testing: filter weighing for particulate (gravimetric PM) analysis
- •University teaching labs in quantitative analysis
Getting accurate results
- •Let the balance warm up. Most manufacturers specify 30–60 minutes from power-on before the first calibration; EMFR coil temperature affects the zero point.
- •Level the balance every time it is moved. A 1° tilt can change the reading measurably because the load vector is no longer vertical.
- •Handle weights and sample vessels with tongs or gloves. A fingerprint is roughly 0.1–1 mg — a full display division of error at 0.1 mg resolution.
- •Weigh by difference for hygroscopic or volatile samples: tare the closed container, add the sample, and re-weigh, rather than dispensing onto an open pan.
- •Ground plastic vessels or use an ioniser. Static on a plastic weigh boat can shift a reading by several milligrams and produce a slow, one-directional drift.
- •Readability (also written as d, or the display division) is the smallest change in mass the display can show. It is not the same as accuracy: a balance reading to 0.01 g may still carry a linearity error of ±0.02 g. Accuracy is bounded by readability, repeatability (standard deviation of repeated loads), and linearity combined.
Frequently asked questions about the PX225D
What are the capacity and readability of the PX225D?
Capacity and readability for the PX225D are listed in the specification table above.
What test weight is needed to calibrate the PX225D?
A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.
How often should the PX225D be calibrated?
Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.
Is the PX225D legal for trade?
A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.
What is the difference between readability and accuracy?
Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.
How fast does the PX225D ship, and can it be repaired?
In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.
PX225D manual summary and troubleshooting
Unpacking and installation
Site the balance on a stone or dedicated anti-vibration bench away from doors, vents and direct sun. Fit the draft shield, pan support and pan, level the bubble, and allow at least 60 minutes (ideally overnight) of powered warm-up before the first weighing.
Calibration and verification
Run internal calibration once warmed up, then verify externally with an ASTM Class 1 or OIML E2 weight. Repeatability should be checked with ten replicate weighings of the same mass — the standard deviation must stay within the balance's stated repeatability. USP <41> users must additionally confirm the minimum sample weight.
Error codes and symptoms
| Symptom | Cause and remedy |
|---|---|
| Unstable / flashing reading | Air movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading. |
| Over-capacity indication (E, EEEE, or ---- ) | Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero. |
| Will not zero at power-up | Something is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle. |
| Calibration fails or rejects the weight | Wrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up. |
| Drifting reading over minutes | Thermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders. |
| Reading creeps after loading | Sample is hygroscopic or electrostatically charged, or the door was closed too quickly. Use a closed vessel and an ioniser. |
Care and re-verification
Handle weights with forceps only, keep the draft shield closed between weighings, and never brush the pan with a hand — use a soft brush.
Need the printed PDF? The official OHAUS Corporation manual library is at OHAUS Corporation documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.