    Ohaus Ranger R71MHD6 6 kg x 0.02g with NTEP Certified Bench Scale

    Ohaus Ranger R71MHD6 6 kg x 0.02g with NTEP Certified Bench Scale

    $3646.00

    $2599.00

    On Sale

    MSRP $3646.00 — you save $1047.00 (29% off)

    Capacity 6 kg × readability 0.02 g.

    Ohaus R71MHD6 – Bench Scale

    Simplifying Even the Most Complex Industrial Applications. For Ranger 7000, there is one resounding theme: it offers the best of every ingenious feature that make OHAUS industrial products the right tools for your toughest weighing jobs. Ranger 7000 boasts the highest resolution, largest display, most application modes and connectivity options, as well as the largest memory library of any industrial bench scale in the OHAUS portfolio.

    Special Features:

    • Advanced Features Take Industrial Weighing to the Next Level – Ranger 7000 has ten advanced application modes for a variety of complex applications which minimize the need for manual calculations, and can also control peripheral devices and/or a scale platform with option kit.
    • Fast Performance and Legal for Trade Certifications assure Accurate Results – With a one second stabilization time, up to 75,000d or 350,000d display resolution and legal for trade certifications, Ranger 7000 provides the precision that cannot be matched by any scale in its class.
    • Sturdy Industrial and Modular Design Support Flexible and Heavy-Duty Use – Ranger 7000 was developed to thrive in rugged and harsh industrial environments. This modular scale was built with IP54 cast metal housing and sealed metal indicator to ensure durability.
    • Cutting-Edge SmarText™ 2.0 Software Powers the Technologically Advanced Ranger 7000 – With SmarText 2.0 software and a 4.3 inch graphic display, the advanced functionality of Ranger 7000 is simple to use with minimal training.
    • 1 year warranty
    Specifications:
    Ohaus – R71MHD6
    Capacity 6 kg
    Readability 0.02 g (0.2 g NTEP)
    Pan Size 8.3 x 8.3″ / 210 x 210 mm
    Capacity x Readability 6 kg x 0.00002 kg
    6,000 g x 0.02 g
    15 lb x 0.00005 lb
    240 oz x 0.001 oz
    Maximum Displayed Resolution 1:300,000
    Certified Capacity x Readability 6 kg x 0.0002 kg
    6,000 g x 0.2 g
    15 lb x 0.0005 lb
    240 oz x 0.01 oz
    Certified/Approved Resolution 1:30,000
    Linearity/Repeatability ±2d
    Weighing Units kg, g, lb, oz, lb:oz
    Application Modes Weighing, Parts Counting, Percent Weighing, Dynamic Weighing (Display Hold)
    Filling, Formulation, Differential Weighing, Density Weighing
    Display 4.3″ TFT Graphic LCD
    Keypad 8 function, 5 quick, 12 numeric membrane keys
    Construction Stainless Steel Platform, Die Cast Housing
    Protection IP54
    Stabilization Time 1 second
    Zeroing Range 2% or 10% of Capacity
    Safe Overload Capacity 150% of Capacity
    Interface Standard RS232, USB Device, USB Host
    Optional Ethernet, 2nd RS232, Remote Base, 2 In/4 Out digital I/O
    Power 100-240 VAC/ 50/60 Hz Universal Power Supply, rechargeable lithium battery (Optional)
    Display Dimensions (W x D x H) 10.5 x 4.6 x 2.8″ / 267 x 118 x 72 mm
    Base Housing Dimensions
    (W x D x minH)
    11 x 11 x 4.5″ / 280 x 280 x 114 mm
    Platform Dimensions
    (W x D x H)
    9.4 x 9.4 x 0.5″ / 240 x 240 x 15 mm
    Net Weight 16 lb / 7.2 kg
    Shipping Weight 20.3 lb / 9.2 kg
    Shipping Dimensions 23.8 x 15.9 x 9.6″ / 605 x 405 x 244 mm
    Calibration InCal™ internal calibration, Span or Linear
    Battery Life 9 hours continous use

    Why buy from EK1200i.com

    • Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
    • Free fast shipping within the mainland USA
    • In-house NIST-traceable calibration available before shipment on request
    • Live phone and email support from working scale technicians in Cypress, Texas
    • Full-service calibration and repair lab for the life of your scale

    Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.

    Request Quote
    Authorized A&D Dealer
    Free Mainland US Shipping
    Expert Support

    Need bulk pricing? Contact us for special pricing on volume orders.

    Specifications

    Manufacturer
    Ohaus
    Model
    R71MHD6
    Instrument class
    Bench scale
    Capacity
    6.6 kg
    Readability (d)
    0.02 g
    Display divisions
    330,000
    SKU / Part number
    OHAUS-R71MHD6-6KG-002
    Price (USD)
    $2599.00
    Availability
    In stock — ships from the USA
    Shipping
    Free ground shipping, mainland USA
    Warranty
    Full manufacturer warranty, registered to the buyer
    Calibration
    NIST-traceable, performed in Cypress, TX

    Capacity in other units

    Grams (g)
    6,600
    Kilograms (kg)
    6.6
    Pounds (lb)
    14.551
    Ounces (oz)
    232.81
    Troy ounces (ozt)
    212.195
    Carats (ct)
    33,000

    What is a bench scale, and how does this one work?

    A bench scale is a mid-capacity platform scale designed to sit on a work surface, typically covering 5 lb to 300 lb with a stainless or painted-steel platter. The R71MHD6 is rated to 6.6 kg with 0.02 g increments. It is the standard instrument for shipping, receiving, portioning, and checkweighing.

    Most bench scales use a single-point aluminium or stainless load cell mounted under the centre of the platter. The cell is corner-load compensated during manufacture so a parcel placed at any corner of the platform reads the same. The indicator applies filtering (digital averaging) to reject vibration, which is why a heavier filter setting gives a steadier but slower reading.

    Where the R71MHD6 is used

    • •Shipping and receiving, parcel and freight rating
    • •Food portioning and ingredient batching
    • •Checkweighing on packaging lines
    • •Retail back-of-house and inventory control
    • •Laboratory and industrial general-purpose weighing

    Getting accurate results

    • •Place the scale on a rigid, level surface; a flexing table introduces reading instability that no filter setting will fix.
    • •Calibrate with a weight at or near capacity, and verify at mid-range afterwards to check linearity.
    • •Check corner (shift) error quarterly: place the same test weight at each corner of the platter; readings should agree within one division.
    • •Keep the platter clean underneath — debris bridging the platter to the base creates a mechanical shunt and false low readings.

    Frequently asked questions about the R71MHD6

    What are the capacity and readability of the R71MHD6?

    The R71MHD6 is rated to 6.6 kg with 0.02 g readability, which is 330,000 display divisions across the range. Subtract the mass of any container or fixture from capacity to get your usable weighing range, because tare does not add capacity back.

    What test weight is needed to calibrate the R71MHD6?

    A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division (0.02 g here), per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.

    How often should the R71MHD6 be calibrated?

    Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.

    Is the R71MHD6 legal for trade?

    A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.

    What is the difference between readability and accuracy?

    Readability is the smallest increment the display can show — 0.02 g on the R71MHD6. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.

    How fast does the R71MHD6 ship, and can it be repaired?

    In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.

    R71MHD6 manual summary and troubleshooting

    Unpacking and installation

    Unpack on the bench where the instrument will live, fit the platter or pan, and connect the supplied adapter. Level the instrument using the feet until the bubble is centred, then let it power up and warm through before the first weighing.

    Calibration and verification

    Run the span calibration routine with a certified test weight at or near full capacity, then verify with a second weight near one third of capacity. Record both readings and the date in a calibration log.

    Error codes and symptoms

    SymptomCause and remedy
    Unstable / flashing readingAir movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading.
    Over-capacity indication (E, EEEE, or ---- )Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero.
    Will not zero at power-upSomething is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle.
    Calibration fails or rejects the weightWrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up.
    Drifting reading over minutesThermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders.

    Care and re-verification

    Keep the platter clean and dry, avoid shock loading, store certified test weights in their case and re-verify after any move.

    Need the printed PDF? The official OHAUS Corporation manual library is at OHAUS Corporation documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.

    Customer reviews for R71MHD6

    No reviews yet. Be the first to review this product.