Ohaus V41XWE3T – Food Scale
The Ohaus Valor 4000 stainless steel water-resistant food scale is designed to improve safety, efficiency and productivity of wet food weighing. A water-resistant design, it sports a host of advanced standard features such as bright LED dual front and rear displays, touch-less tare sensor, knife-proof keyboard overlay, lightening fast settle time and rechargeable battery for easy portability.
Special Features:
- NTEP Legal for Trade
- NSF AND USDA Approvals
- Stainless Steel Housing
- Stainless Steel Pan
- Weighing, Percent Weighing, Checkweighing, Accumulation
- 50 Hours of Battery Life From Internal Rechargeable Sealed Lead Acid Battery
- Front and Rear LED Displays
- Touchless Tare Sensor
- 3 LED (yellow, green, red) checkweighing lights
- Transport Handle
- Knife-proof, Chemical Resistant Overlay Keyboard
- Bubble Level Indicator
- Adjustable Leveling Feet
- External Calibration
- 1 year warranty
| Ohaus – V41XWE3T | |
|---|---|
| Capacity | 6 lbs / 3kg |
| Readability | 0.001 lb / 0.5g |
| Pan Size | 7.5 x 9.5 in / 190 x 242 mm |
| Certified Capacity x Readability | 3000 g x 1 g |
| Construction | Stainless steel housing, stainless steel platform |
| Weighing Units | kg, g, lb, oz, lb:oz |
| Application Modes | Weighing, Checkweighing, Percent Weighing, Accumulation |
| Display | 7 Segment, 6 digital / 20.5mm high red LED dual display |
| Checkweighing Indicators | 3 LED (yellow, green, red) |
| Display Indicators | Stability, Center of Zero, Net, Battery Status, IR sensor & Accumulation |
| Keypad | 4 mechanical keys plus one tare touchless sensor |
| Zero Range | 4% or 20% of full scale capacity |
| Tare Range | Full capacity by subtraction |
| Stabilization Time | 1 second |
| Safe Overload Capacity | 150% of capacity |
| Power | 100-240 VAC / 50-60 Hz internal universal power supply, internal rechargeable lead acid battery |
| Battery Life | 50 hours continuous use |
| Calibration | External |
| Operating Temperature Range | -10° C to 40° C, 10% to 95% RH, non-condensing |
| Ingress Protection | IPX8 |
| Pan Size (W x L) | 7.5 x 9.5 in / 190 x 242 mm |
| Scale Dimensions (W x L x H) | 11.4 x 10.1 x 4.9 in / 288 x 256 x 124mm |
| Shipping Dimensions (W x L x H) | 16 x 15 x 9 / 410 x 370 x 220mm |
| Net Weight | 8.6 lb x 3.9kg |
| Shipping Weight | 11 lb x 4.9kg |
Why buy from EK1200i.com
- Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
- Free fast shipping within the mainland USA
- In-house NIST-traceable calibration available before shipment on request
- Live phone and email support from working scale technicians in Cypress, Texas
- Full-service calibration and repair lab for the life of your scale
Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.
Need bulk pricing? Contact us for special pricing on volume orders.
Specifications
- Manufacturer
- Ohaus
- Model
- V41XWE3T
- Instrument class
- Bench scale
- Capacity
- 3 kg
- SKU / Part number
- OHAUS-V41XWE3T-3KG
- Price (USD)
- $529.00
- Availability
- In stock — ships from the USA
- Shipping
- Free ground shipping, mainland USA
- Warranty
- Full manufacturer warranty, registered to the buyer
- Calibration
- NIST-traceable, performed in Cypress, TX
Capacity in other units
- Grams (g)
- 3,000
- Kilograms (kg)
- 3
- Pounds (lb)
- 6.614
- Ounces (oz)
- 105.82
- Troy ounces (ozt)
- 96.452
- Carats (ct)
- 15,000
What is a bench scale, and how does this one work?
A bench scale is a mid-capacity platform scale designed to sit on a work surface, typically covering 5 lb to 300 lb with a stainless or painted-steel platter. The V41XWE3T is rated to 3 kg. It is the standard instrument for shipping, receiving, portioning, and checkweighing.
Most bench scales use a single-point aluminium or stainless load cell mounted under the centre of the platter. The cell is corner-load compensated during manufacture so a parcel placed at any corner of the platform reads the same. The indicator applies filtering (digital averaging) to reject vibration, which is why a heavier filter setting gives a steadier but slower reading.
Where the V41XWE3T is used
- •Shipping and receiving, parcel and freight rating
- •Food portioning and ingredient batching
- •Checkweighing on packaging lines
- •Retail back-of-house and inventory control
- •Laboratory and industrial general-purpose weighing
Getting accurate results
- •Place the scale on a rigid, level surface; a flexing table introduces reading instability that no filter setting will fix.
- •Calibrate with a weight at or near capacity, and verify at mid-range afterwards to check linearity.
- •Check corner (shift) error quarterly: place the same test weight at each corner of the platter; readings should agree within one division.
- •Keep the platter clean underneath — debris bridging the platter to the base creates a mechanical shunt and false low readings.
Frequently asked questions about the V41XWE3T
What are the capacity and readability of the V41XWE3T?
The V41XWE3T is rated to 3 kg. Subtract the mass of any container or fixture from capacity to get your usable weighing range, because tare does not add capacity back.
What test weight is needed to calibrate the V41XWE3T?
A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.
How often should the V41XWE3T be calibrated?
Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.
Is the V41XWE3T legal for trade?
A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.
What is the difference between readability and accuracy?
Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.
How fast does the V41XWE3T ship, and can it be repaired?
In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.
V41XWE3T manual summary and troubleshooting
Unpacking and installation
Unpack on the bench where the instrument will live, fit the platter or pan, and connect the supplied adapter. Level the instrument using the feet until the bubble is centred, then let it power up and warm through before the first weighing.
Calibration and verification
Run the span calibration routine with a certified test weight at or near full capacity, then verify with a second weight near one third of capacity. Record both readings and the date in a calibration log.
Error codes and symptoms
| Symptom | Cause and remedy |
|---|---|
| Unstable / flashing reading | Air movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading. |
| Over-capacity indication (E, EEEE, or ---- ) | Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero. |
| Will not zero at power-up | Something is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle. |
| Calibration fails or rejects the weight | Wrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up. |
| Drifting reading over minutes | Thermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders. |
Care and re-verification
Keep the platter clean and dry, avoid shock loading, store certified test weights in their case and re-verify after any move.
Need the printed PDF? The official OHAUS Corporation manual library is at OHAUS Corporation documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.
Customer reviews for V41XWE3T
No reviews yet. Be the first to review this product.