Back to all A&D scales
    Prime Scales Floor Scale Cable 4pin + 4pin 30′ Long

    Prime Scales Floor Scale Cable 4pin + 4pin 30′ Long

    $78.00

    special 30′ cable 4 pin round both end for Prime scales floor scale with PS-IN202 LED and LCD, also PS-IN108

    Floor and pallet scales handle drum, pallet and freight weighing at ground level. Consider deck size, capacity, ramp access and washdown requirements.

    At a glance

    • Brand: Optima
    • Category: Floor Scale

    Not sure this is the right model for your application? Our technicians match scales to real-world jobs every day and will confirm capacity, readability and legal-for-trade requirements before you order.

    Why buy from EK1200i.com

    • Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
    • Free fast shipping within the mainland USA
    • In-house NIST-traceable calibration available before shipment on request
    • Live phone and email support from working scale technicians in Cypress, Texas
    • Full-service calibration and repair lab for the life of your scale

    Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.

    Request Quote
    Authorized A&D Dealer
    Free Mainland US Shipping
    Expert Support

    Need bulk pricing? Contact us for special pricing on volume orders.

    Specifications

    Manufacturer
    Optima
    Model
    Prime Scales
    Instrument class
    Floor scale
    SKU / Part number
    OPTIM-PRIMESCALESFLO-2
    Price (USD)
    $78.00
    Availability
    In stock — ships from the USA
    Shipping
    Free ground shipping, mainland USA
    Warranty
    Full manufacturer warranty, registered to the buyer
    Calibration
    NIST-traceable, performed in Cypress, TX

    What is a floor scale, and how does this one work?

    A floor scale is a low-profile, high-capacity platform installed at or near ground level for pallets, drums, and carts. A typical unit uses four shear-beam load cells at the platform corners feeding a summing junction box and a separate indicator.

    Each of the four shear-beam cells carries roughly one quarter of the load. Their millivolt outputs are combined in a junction box, where trim potentiometers or digital corner adjustment equalise the cells so the reading is the same wherever the load sits on the deck. Because total capacity is divided across four cells, a 5,000 lb floor scale is built from four 2,500 lb cells to allow for uneven and dynamic loading.

    Where the Prime Scales is used

    • •Pallet and freight weighing in warehousing and 3PL
    • •Drum and tote filling in chemical processing
    • •Scrap, recycling, and waste-stream measurement
    • •Manufacturing WIP and raw-material receiving
    • •Livestock and agricultural bulk handling

    Getting accurate results

    • •Anchor or shim the scale so all four feet carry load; an unloaded corner destroys accuracy and overloads the other three cells.
    • •Perform a corner (section) test at commissioning and annually: a test load at each corner should agree within one division.
    • •Never weld on or near the platform without disconnecting the cells — welding current through a load cell destroys it.
    • •Keep the pit or under-deck area free of debris; anything touching the deck bypasses the cells.

    Frequently asked questions about the Prime Scales

    What are the capacity and readability of the Prime Scales?

    Capacity and readability for the Prime Scales are listed in the specification table above.

    What test weight is needed to calibrate the Prime Scales?

    A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.

    How often should the Prime Scales be calibrated?

    Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.

    Is the Prime Scales legal for trade?

    A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.

    What is the difference between readability and accuracy?

    Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.

    How fast does the Prime Scales ship, and can it be repaired?

    In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.

    Prime Scales manual summary and troubleshooting

    Unpacking and installation

    Set the deck on a flat, cured concrete floor and shim each foot until all four load cells carry load. Route the summing-junction cable clear of forklift traffic and secure the indicator at eye height.

    Calibration and verification

    After levelling, perform a corner (shift) test: place a known weight of roughly one third of capacity over each load cell in turn. Readings must agree within the permitted error before span calibration is trusted.

    Error codes and symptoms

    SymptomCause and remedy
    One corner reads lowFoot not carrying load or a failed load cell. Re-shim, then measure cell output at the junction box.
    Reading jumps with forklift trafficCable damage or a loose junction-box connection. Inspect and re-terminate.
    Over-capacity indication (E, EEEE, or ---- )Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero.
    Will not zero at power-upSomething is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle.

    Care and re-verification

    Keep debris out from under the deck, wash down only to the stated IP rating, and re-run the corner test after any move.

    Need the printed PDF? The official Optima Scale Manufacturing manual library is at Optima Scale Manufacturing documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.

    Customer reviews for Prime Scales

    No reviews yet. Be the first to review this product.