Radwag MA 50.X2.A Moisture Analyzer
$1960.00
On SaleMSRP $2540.00 — you save $580.00 (23% off)
We negotiate the price.
MA X2 moisture analyzers are hi-tech measuring instruments intended for quick determination of relative moisture content, dry mass content and other parameters in samples of different substances.
MA.X2.A series is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors
Such solution allows:
|
- Automatic opening and closing of the drying chamber
- 5” capacitive colour touchpad
- Modern interface
- Uncomplicated, intuitive operation
- Programmable display
- Drying profiles (standard, mild, step, fast)
- GLP/GMP printouts-reports
- Repeatable and customized applications
- Work optimization due to the use of halogen lamps
An additional element for moisture analyzers that improves their functionality is a water vapour permeability determination set used in tanning industry for determining hygienic properties of leather.DATABASES:
Information system of X2 series moisture analyzers is based on 6 databases, allowing many users to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis.
Collected data is registered in 8 databases:
- Products (up to 5000 products)
- Users (up to 100 users)
- Packaging (up to 100 packagings)
- Customers(up to 1000 customers)
- Drying programs (up to 200 drying programs)
- Drying process reports (up to 5000 drying process reports)
- Ambient conditions (up to 10000 records)
- Weighings (up to 50000 records)
- % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage,
- % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated,
- % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process,
- g – the sample mass after drying.
Metrological parametersPhysical parametersCommunication interfaceElectrical parametersEnvironmental conditionsFeatures of use
| Maximum capacity [Max] | 50
g |
| Readability [d] | 1
mg |
| Tare range | -50
g |
| Adjustment | external
|
| Maximum sample weight | 50
g |
| Heating module | IR emitter
|
| Moisture content repeatability | +/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g)
|
| Moisture content readability | 0.001%
|
| Drying temperature range | max 160
°C |
| Leveling system | manual
|
| Display | 5” graphic color touchscreen
|
| Weighing pan dimensions | ø90, h= 8
mm |
| Packaging dimensions | 470×380×336
mm |
| Net weight | 5.2
kg |
| Gross weight | 6.7
kg |
| Protection class | IP 43
|
| Maximum sample height | 20
mm |
| Communication interface | RS232¹, USB-A, USB-B, Ethernet, Wi-Fi®
|
| Power supply | 100V – 120V AC 50/60Hz or 200V-240V AC 50/60Hz
|
| Power consumption | 6 W
|
| Heating module power | 450 W
|
| Operating temperature | +10 — +40
°C |
| Drying method | 4 drying profiles (standard, fast, step, mild)
|
| Finish mode | 4 modes (automatic, manual, time-defined, user-defined)
|
| Additional functions | sample traceability |
Why buy from EK1200i.com
- Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
- Free fast shipping within the mainland USA
- In-house NIST-traceable calibration available before shipment on request
- Live phone and email support from working scale technicians in Cypress, Texas
- Full-service calibration and repair lab for the life of your scale
Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.
Need bulk pricing? Contact us for special pricing on volume orders.
Specifications
- Manufacturer
- Radwag
- Model
- MA-50
- Instrument class
- Moisture analyzer
- SKU / Part number
- RADWA-MA50-2
- Price (USD)
- $1960.00
- Availability
- In stock — ships from the USA
- Shipping
- Free ground shipping, mainland USA
- Warranty
- Full manufacturer warranty, registered to the buyer
- Calibration
- NIST-traceable, performed in Cypress, TX
What is a moisture analyzer, and how does this one work?
A moisture analyzer determines moisture content by loss on drying: it weighs a sample, heats it with a halogen or infrared element, and reports the percentage of mass lost as the sample dries to constant weight. The result is a moisture percentage in minutes rather than the hours an oven method requires.
The instrument is a precision balance with a heating chamber above the pan. It records initial wet mass, ramps the heater to a set temperature, and samples mass continuously. A switch-off criterion — fixed time, or a rate threshold such as less than 1 mg change per 50 seconds — ends the test. Moisture % = (wet mass − dry mass) ÷ wet mass × 100.
Where the MA-50 is used
- •Food processing: grain, flour, dairy, snack, and meat moisture QC
- •Plastics: resin and pellet moisture before injection moulding
- •Pharmaceutical granulation and drying endpoint control
- •Agriculture: hay, feed, and seed moisture
- •Paper, textile, and wood products
Getting accurate results
- •Spread the sample thin and evenly across the pan — 5 g in a uniform layer dries far more reproducibly than a 10 g mound.
- •Use disposable glass-fibre pads for liquids and pastes to increase surface area.
- •Run each new material three times to establish repeatability before adopting a method.
- •Record temperature, sample mass, and switch-off criterion with every result; a moisture figure without its method is not comparable to anything.
Frequently asked questions about the MA-50
What are the capacity and readability of the MA-50?
Capacity and readability for the MA-50 are listed in the specification table above.
What test weight is needed to calibrate the MA-50?
A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.
How often should the MA-50 be calibrated?
Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.
Is the MA-50 legal for trade?
A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.
What is the difference between readability and accuracy?
Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.
How fast does the MA-50 ship, and can it be repaired?
In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.
MA-50 manual summary and troubleshooting
Unpacking and installation
Site away from draughts and above a heat-tolerant surface. Fit the pan handler and a fresh aluminium sample pan, and confirm the exhaust above the unit is unobstructed.
Calibration and verification
Verify the weighing side with a certified weight, then verify the temperature side with a temperature calibration kit. Fix the sample mass, drying temperature and switch-off criterion in a written method; results are only comparable within the same method.
Error codes and symptoms
| Symptom | Cause and remedy |
|---|---|
| Result varies between operators | Sample mass or spreading differs. Standardise mass and spread the sample evenly and thinly. |
| Drying never ends | Switch-off criterion too tight for the sample. Loosen the criterion or use a timed method. |
| Unstable / flashing reading | Air movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading. |
| Over-capacity indication (E, EEEE, or ---- ) | Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero. |
Care and re-verification
Replace the halogen lamp per the manual's hour rating, keep the heating chamber clean, and never dry solvents or flammables.
Need the printed PDF? The official RADWAG Balances and Scales manual library is at RADWAG Balances and Scales documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.
Customer reviews for MA-50
No reviews yet. Be the first to review this product.