Back to all A&D scales
    Sartorius GCL603i-2S Carat Balance Jewelry Scale with Internal Cal 600 x 0.001

    Sartorius GCL603i-2S Carat Balance Jewelry Scale with Internal Cal 600 x 0.001

    $1568.00

    Secure operating procedures and precise weighing results are indispensable for determining the weight of precious metals and gemstones. Fast work processes and harsh environmental conditions require robust balances that provide consistently reliable and accurate results

    Sartorius offers you a wide array of gold and carat balances. This selection of analytical and precision weighing instruments includes verified models that meet the metrological requirements for legal-for-trade weight measurements.

    Sartorius GCL Carat Balances

    • Draft shield with a weighing chamber height of 160 mm
    • Automatic, built-in calibration and adjustment function
    • Monolithic weigh cell Hybrid display (LED and touch technology)

    Sartorius GL Gold Balances

    • Milligram balances feature a draft shield with a weighing
    • chamber height of 160 mm Automatic, built-in calibration and adjustment function
    • available as an option Hybrid display (LED and touch technology)
    600 ct x 0.001 ct Pan size: Dia 90 mm

    Why buy from EK1200i.com

    • Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
    • Free fast shipping within the mainland USA
    • In-house NIST-traceable calibration available before shipment on request
    • Live phone and email support from working scale technicians in Cypress, Texas
    • Full-service calibration and repair lab for the life of your scale

    Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.

    Request Quote
    Authorized A&D Dealer
    Free Mainland US Shipping
    Expert Support

    Need bulk pricing? Contact us for special pricing on volume orders.

    Specifications

    Manufacturer
    Sartorius
    Model
    Sartorius GCL603i-2S
    Instrument class
    Jewelry scale
    SKU / Part number
    SARTO-GCL603I-2S-0001
    Price (USD)
    $1568.00
    Availability
    In stock — ships from the USA
    Shipping
    Free ground shipping, mainland USA
    Warranty
    Full manufacturer warranty, registered to the buyer
    Calibration
    NIST-traceable, performed in Cypress, TX

    What is a jewelry scale, and how does this one work?

    A jewelry scale is a high-resolution balance that reads in carats, grams, pennyweight, and troy ounces for pricing precious metals and gemstones. One metric carat is exactly 0.2 g; one pennyweight (dwt) is 1.55517 g; one troy ounce is 31.1035 g.

    Jewelry scales are precision balances with an extended unit set and, in higher grades, electromagnetic force restoration for stability at 0.001 g or 0.005 ct. Because a small error translates directly into money at bullion prices, these instruments emphasise repeatability and drift control over capacity.

    Where the Sartorius GCL603i-2S is used

    • •Gold, silver, and platinum buying and refining counters
    • •Gemstone grading and carat weighing
    • •Jewelry manufacturing, casting, and alloy formulation
    • •Pawn shops and estate buyers
    • •Coin dealing and bullion verification

    Getting accurate results

    • •Calibrate daily at a buying counter with an ASTM Class 1 or 2 weight, and log it — the log is your defence in a dispute.
    • •Weigh on a solid, isolated surface away from the door and HVAC vents.
    • •Let items reach room temperature; a warm item creates convection that reads light.
    • •Keep the pan and shield clean — the loss from accumulated dust is real money over a year.
    • •Readability (also written as d, or the display division) is the smallest change in mass the display can show. It is not the same as accuracy: a balance reading to 0.01 g may still carry a linearity error of ±0.02 g. Accuracy is bounded by readability, repeatability (standard deviation of repeated loads), and linearity combined.

    Frequently asked questions about the Sartorius GCL603i-2S

    What are the capacity and readability of the Sartorius GCL603i-2S?

    Capacity and readability for the Sartorius GCL603i-2S are listed in the specification table above.

    What test weight is needed to calibrate the Sartorius GCL603i-2S?

    A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.

    How often should the Sartorius GCL603i-2S be calibrated?

    Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.

    Is the Sartorius GCL603i-2S legal for trade?

    A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.

    What is the difference between readability and accuracy?

    Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.

    How fast does the Sartorius GCL603i-2S ship, and can it be repaired?

    In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.

    Sartorius GCL603i-2S manual summary and troubleshooting

    Unpacking and installation

    Unpack on the bench where the instrument will live, fit the platter or pan, and connect the supplied adapter. Level the instrument using the feet until the bubble is centred, then let it power up and warm through before the first weighing.

    Calibration and verification

    Run the span calibration routine with a certified test weight at or near full capacity, then verify with a second weight near one third of capacity. Record both readings and the date in a calibration log.

    Error codes and symptoms

    SymptomCause and remedy
    Unstable / flashing readingAir movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading.
    Over-capacity indication (E, EEEE, or ---- )Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero.
    Will not zero at power-upSomething is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle.
    Calibration fails or rejects the weightWrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up.
    Drifting reading over minutesThermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders.

    Care and re-verification

    Keep the platter clean and dry, avoid shock loading, store certified test weights in their case and re-verify after any move.

    Need the printed PDF? The official Sartorius Lab Instruments manual library is at Sartorius Lab Instruments documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.

    Customer reviews for Sartorius GCL603i-2S

    No reviews yet. Be the first to review this product.