Sartorius Secura324-1S Analytical Balance, 320g x 0.1mg, Internal Calibration
$4738.00
Capacity 320 g × readability 0.1 mg.
Please contact for better price. Our price is negotiable.
Features
The new Secura® is a laboratory balance that does far more than set new standards in metrological specifications. Beyond its technical specs, Secura® also gives you the security and serenity of knowing that you have done everything right according to best practices to ensure the quality of your measurement results, compliance with regulatory requirements and your efficiency as well
First, the new operating concept of Secura® will noticeably ease your daily workload during weighing and, second, its APC function – Advanced Pharma Compliance – will relieve you from tedious and time-consuming documentation and monitoring tasks.
These two benefits, in combination with legendary Sartorius quality, make reliable weighing in regulated areas easier than ever before
Always Correctly Leveled with Sartorius LevelControl
Secura® has an optoelectronic sensor that continuously checks to see if the balance is perfectly level. If it detects any outof- tolerances, you will be immediately alerted to this pending risk and see specific guidance prompts to help you level the balance. Output of the weighing data over the interface port will be temporarily interrupted until the balance has been correctly leveled again.
This means you can rest assured knowing that only correct data is transmitted. During leveling, you will not have to change your seated position. More importantly, when working with toxic substances under a laboratory fume hood, you will not have to lean over the balance while leveling it. As a result, Secura® rules out the risk of health hazards.
Regulatory Compliance with Expert Support
Do you use your Secura® or other instruments in a regulated area and have to comply with a multitude of requirements, regulations and directives? Relax. Sartorius Lab Products & Services will provide you with the appropriate expert services specifically tailored to ensure compliance with the strict requirements of the pharmaceutical industry – and not just for balances
Risk Minimization – IQ | OQ Documentation
Do you need qualification documents as proof of suitability to be able to use your Secura® in a regulated area? Sartorius Lab Products & Services will support you by providing trained specialists on site. We will generate the documents you need according to risk-based test plans and test reports for installation and operational qualification.
Stress-Free USP Minimum Sample Weight Measurement
Compliance with the USP minimum sample weight requirements with absolute process reliability? No problem for the new Secura®.
The display clearly indicates when the minimum sample weight is below the required minimum limit. In addition, the balance will temporarily block data transfer to a printer or a device connected to its interface port. This gives you peace of mind knowing that inadequate data cannot be inadvertently processed further.
Our specially trained service staff will determine the minimum sample weight for you right at the balance’s site of installation, program it into your Secura® and attach a corresponding verification seal to the balance.
Best Results – Quality Documentation Made Easy
Secura® features a Cal Audit Trail function to document the quality of each weigh-in procedure you perform. Each adjustment procedure, including any non-conformities, are recorded by the balance, can be viewed on the touch screen and, if necessary, can be transferred over the balance’s interface to a computer or to a Sartorius laboratory printer.
No Risk Due to Temperature Fluctuations
Temperature fluctuations have an influence on the accuracy of your weighing results.
This is why every Secura® comes equipped with the internal adjustment function isoCAL that ensures consistently accurate results.
Secura® can be configured to prompt you to launch this procedure or to have isoCAL take care of this as soon as an activation threshold is reached.
The Cal Audit Trail function records each isoCAL procedure performed so it can be traced for your quality assurance.
Cleanability to Secure the Best Results
Cleanliness is one of the main prerequisites in the laboratory to prevent contamination and ensure work area safety.
That’s why Sartorius placed a premium on designing Secura® to enable easy and thorough cleaning.
Sleek, resistant surfaces plus clear contours and few edges ensure that Secura® will help you stay compliant with all hygiene requirements.
Security by Password Protection
Secura® comes with password protection to restrict adjustment of the balance settings only to authorized persons. If you set a password, all functions that could change the metrological performance specifications are inactivated.
Interactive User Guidance for Fast GLP- | GMP-Compliant Printouts
If you require traceable documents, Secura® will guide you through the steps for obtaining GLP- | GMP-compliant printouts. The novel user guidance will support you especially for working with traceable sample identification. Used in conjunction with the new premium YDP30 laboratory printer, which is automatically detected by Secura®, the balance generates printouts of the results on standard printer paper or on continuous labels.
Specifications & Description
| Capacity(g) x Readability (mg) | 320 g x 0.1 mg |
| Reproducibility (std deviation) milligrams (mg) | ± 0.1 mg |
| Linearity milligrams (mg) | ± 0.3 mg |
| Response Time (average) | 2 seconds |
| Tare Range | FULL to Capacity |
| Selectable Weight Units | g, ct, mom, kg, lb, oz, ozt, tlh, tls, tlt, GN, dwt, mg, parts | lb, tlc, Kt, tol, bat, MS, N |
| Selectable Application Programs | Counting, Weighing in percent, Density determination, Peak hold, Unstable condition, Checkweighing, Mixing, Conversion, Statistics, Components |
| Languages | English, German, French, Spanish, Italian, Russian, Chinese, Polish, Japanese, Portuguese |
| Display | Touch screen with Sartorius graphical user interface |
| Allowable Ambient Operating Temperature | 10° C to 30° C (50° F to 86° F) |
| Sensitivity Drift (10° – 30°C/50°F-86°F) |
± 1 ppm / °K |
| Motorized Internal Calibration | YES |
| External Calibration | 200g Optional, not included |
| Pan Size | ø90 mm / 3.5 in |
| Draft Shield Chamber Height (from pan to top of glass door) |
218 mm / 8.58 in |
| Dimensions (entire balance) W x D x H |
218 x 359 x 319 mm 8.6 x 14.1 x 12.6 in |
| Interface | mini USB |
| Weighing Below | Yes |
| Minimum sample weight according to USP (typical) | 0.082 grams |
| Leveling | Manual with two front leveling feet with the assistance of optoelectronic level sensor with alarm function and interactive user guidance for reliable and safe leveling |
| GLP/GMP Data Capability | YES GLP printout capability |
| Internal Clock | YES |
| AC Power Source | AC Adapter 120 VAC |
| Housing Design | Aluminum Die-cast base with coated ABS top housing |
| Weigh Sensor | Magnetic Force Restoration |
| Place of Origin | Germany |
| Standard Equipment | 120V AC Adapter, In Use Dust Cover, Manual |
| Optional Accessories | YDP40 Printer, YRB11Z External battery pack, YCC03-D09 Mini USB/RS232-9 pin, YCC04-D09 Data Cable mini USB to USB A, external calibration mass |
| Warranty | 2 years manufacturer’s warranty |
Why buy from EK1200i.com
- Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
- Free fast shipping within the mainland USA
- In-house NIST-traceable calibration available before shipment on request
- Live phone and email support from working scale technicians in Cypress, Texas
- Full-service calibration and repair lab for the life of your scale
Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.
Need bulk pricing? Contact us for special pricing on volume orders.
Specifications
- Manufacturer
- Sartorius
- Model
- Sartorius Secura324-1S
- Instrument class
- Analytical balance
- Capacity
- 320 g
- Readability (d)
- 0.1 g
- Display divisions
- 3,200
- SKU / Part number
- SARTO-SARTORIUSSECUR-320G-01-2
- Price (USD)
- $4738.00
- Availability
- In stock — ships from the USA
- Shipping
- Free ground shipping, mainland USA
- Warranty
- Full manufacturer warranty, registered to the buyer
- Calibration
- NIST-traceable, performed in Cypress, TX
Capacity in other units
- Grams (g)
- 320
- Kilograms (kg)
- 0.32
- Pounds (lb)
- 0.705
- Ounces (oz)
- 11.29
- Troy ounces (ozt)
- 10.288
- Carats (ct)
- 1,600
What is a analytical balance, and how does this one work?
An analytical balance is a laboratory instrument that measures mass to 0.1 mg (0.0001 g) or finer inside an enclosed draft shield. The Sartorius Secura324-1S has a 320 g capacity and 0.1 g readability, giving 3,200 display divisions. At this resolution, air currents, temperature gradients, static charge, and building vibration all become measurable sources of error, which is why analytical balances use a windshield, a level indicator, and often internal motorised calibration.
Analytical balances use electromagnetic force restoration (EMFR), not a strain-gauge load cell. A coil sits in a permanent magnetic field; when mass is applied, a position sensor detects the deflection and the servo loop increases coil current until the pan returns to its null position. The current required is directly proportional to the applied force, so the reading is derived from a measured electrical quantity rather than from mechanical deformation. This is what makes 0.1 mg resolution and long-term stability possible.
Where the Sartorius Secura324-1S is used
- •Analytical chemistry: standard and reagent preparation, gravimetric analysis
- •Pharmaceutical QC and compounding under USP 41/1251
- •Materials research, catalyst and polymer sample preparation
- •Environmental testing: filter weighing for particulate (gravimetric PM) analysis
- •University teaching labs in quantitative analysis
Getting accurate results
- •Let the balance warm up. Most manufacturers specify 30–60 minutes from power-on before the first calibration; EMFR coil temperature affects the zero point.
- •Level the balance every time it is moved. A 1° tilt can change the reading measurably because the load vector is no longer vertical.
- •Handle weights and sample vessels with tongs or gloves. A fingerprint is roughly 0.1–1 mg — a full display division of error at 0.1 mg resolution.
- •Weigh by difference for hygroscopic or volatile samples: tare the closed container, add the sample, and re-weigh, rather than dispensing onto an open pan.
- •Ground plastic vessels or use an ioniser. Static on a plastic weigh boat can shift a reading by several milligrams and produce a slow, one-directional drift.
- •Readability (also written as d, or the display division) is the smallest change in mass the display can show. It is not the same as accuracy: a balance reading to 0.01 g may still carry a linearity error of ±0.02 g. Accuracy is bounded by readability, repeatability (standard deviation of repeated loads), and linearity combined.
Frequently asked questions about the Sartorius Secura324-1S
What are the capacity and readability of the Sartorius Secura324-1S?
The Sartorius Secura324-1S is rated to 320 g with 0.1 g readability, which is 3,200 display divisions across the range. Subtract the mass of any container or fixture from capacity to get your usable weighing range, because tare does not add capacity back.
What test weight is needed to calibrate the Sartorius Secura324-1S?
A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division (0.1 g here), per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.
How often should the Sartorius Secura324-1S be calibrated?
Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.
Is the Sartorius Secura324-1S legal for trade?
A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.
What is the difference between readability and accuracy?
Readability is the smallest increment the display can show — 0.1 g on the Sartorius Secura324-1S. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.
How fast does the Sartorius Secura324-1S ship, and can it be repaired?
In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.
Sartorius Secura324-1S manual summary and troubleshooting
Unpacking and installation
Site the balance on a stone or dedicated anti-vibration bench away from doors, vents and direct sun. Fit the draft shield, pan support and pan, level the bubble, and allow at least 60 minutes (ideally overnight) of powered warm-up before the first weighing.
Calibration and verification
Run internal calibration once warmed up, then verify externally with an ASTM Class 1 or OIML E2 weight. Repeatability should be checked with ten replicate weighings of the same mass — the standard deviation must stay within the balance's stated repeatability. USP <41> users must additionally confirm the minimum sample weight.
Error codes and symptoms
| Symptom | Cause and remedy |
|---|---|
| Unstable / flashing reading | Air movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading. |
| Over-capacity indication (E, EEEE, or ---- ) | Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero. |
| Will not zero at power-up | Something is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle. |
| Calibration fails or rejects the weight | Wrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up. |
| Drifting reading over minutes | Thermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders. |
| Reading creeps after loading | Sample is hygroscopic or electrostatically charged, or the door was closed too quickly. Use a closed vessel and an ioniser. |
Care and re-verification
Handle weights with forceps only, keep the draft shield closed between weighings, and never brush the pan with a hand — use a soft brush.
Need the printed PDF? The official Sartorius Lab Instruments manual library is at Sartorius Lab Instruments documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.
Customer reviews for Sartorius Secura324-1S
No reviews yet. Be the first to review this product.