Back to all A&D scales
    Torrey EQB 100/200 Portable Bench Scale NTEP

    Torrey EQB 100/200 Portable Bench Scale NTEP

    $291.00

    Features

    EQB-100/200 Shipping & Receiving Bench Scale

    The EQB Series Bench Scales from TOR REY are well-suited for shipping and receiving applications, teaming high performance, accuracy and flexibility to deliver an incredible value for your business.

    The EQB Series (EQB-100/200 x .05 lbs) is equipped with a handlebar to allow for easy transport around the stockroom and production floor. Built to last, our scales feature an AC adapter and a built-in rechargeable battery with an auto power-off function to save power. The large steel base is designed to handle the demands of everyday industrial weighing. With a footprint of 19″ x 15″, this power scale meets the needs of your business while requiring minimal space.

    The EQB Series scales also feature an easy-to-read display mounted on a 23″ steel pillar. Attractively designed and touchy enough for everyday professional use, the EQB Series scales will be a welcomed addition to your business.

    Whether you’re a storage company, market, foundry, manufacturer or office supplier, the EQB Series will meet the weighing needs of your business. So if you need a dependable and affordable shipping/receiving bench scale, choose the EQB Series from TOR REY.

    SPECIFICATIONS:

    • EQB-100/200 x .05 lbs
    • Steel Construction with Pillar Mounted Display
    • 19″ x 15″ Platter
    • Built-In Rechargeable Battery
    • AC Adapter
    • Toggles Between KG/LB

    IDEAL FOR:

    • Storage Companies
    • Markets
    • Shipping Departments
    • Household Suppliers
    • Steel & Aluminum Foundries
    • Office Suppliers
    • Manufacturers

    EQB Series Shipping Receiving Scales
    Model EQB 100/200
    Capacity 200 lb x 0.05 lb
    Minimum division 100 kg x 0.02 kg
    Display Liquid crystal display
    Backlight Included
    Power Supply 110v/60hz (220v/50 hz Optional)
    Power supply adapter Included
    Cars lighter adapter Optional
    Rechargeable Battery Included (200 hours approximmately)
    Serial port Included
    Plate Dimensions 38 x 48 cm (15 x19” IN)
    Maximum tare 25 kg/50 lb
    Operation temperature -10 to 40 °C (14 to 104 °F)
    Net weight 16.1 kg / 35.5 lb
    Shipping weight 20.3 kg / 44.7 lb

    Why buy from EK1200i.com

    • Authorized dealer since 1998 — new, factory-sealed equipment with the full manufacturer warranty
    • Free fast shipping within the mainland USA
    • In-house NIST-traceable calibration available before shipment on request
    • Live phone and email support from working scale technicians in Cypress, Texas
    • Full-service calibration and repair lab for the life of your scale

    Specifications are published by the manufacturer and may change without notice. Contact us if you need a current datasheet or help matching a model to your application.

    Request Quote
    Authorized A&D Dealer
    Free Mainland US Shipping
    Expert Support

    Need bulk pricing? Contact us for special pricing on volume orders.

    Specifications

    Manufacturer
    Torrey
    Model
    EQB-100
    Instrument class
    Bench scale
    SKU / Part number
    TORRE-EQB100-200
    Price (USD)
    $291.00
    Availability
    In stock — ships from the USA
    Shipping
    Free ground shipping, mainland USA
    Warranty
    Full manufacturer warranty, registered to the buyer
    Calibration
    NIST-traceable, performed in Cypress, TX

    What is a bench scale, and how does this one work?

    A bench scale is a mid-capacity platform scale designed to sit on a work surface, typically covering 5 lb to 300 lb with a stainless or painted-steel platter. It is the standard instrument for shipping, receiving, portioning, and checkweighing.

    Most bench scales use a single-point aluminium or stainless load cell mounted under the centre of the platter. The cell is corner-load compensated during manufacture so a parcel placed at any corner of the platform reads the same. The indicator applies filtering (digital averaging) to reject vibration, which is why a heavier filter setting gives a steadier but slower reading.

    Where the EQB-100 is used

    • •Shipping and receiving, parcel and freight rating
    • •Food portioning and ingredient batching
    • •Checkweighing on packaging lines
    • •Retail back-of-house and inventory control
    • •Laboratory and industrial general-purpose weighing

    Getting accurate results

    • •Place the scale on a rigid, level surface; a flexing table introduces reading instability that no filter setting will fix.
    • •Calibrate with a weight at or near capacity, and verify at mid-range afterwards to check linearity.
    • •Check corner (shift) error quarterly: place the same test weight at each corner of the platter; readings should agree within one division.
    • •Keep the platter clean underneath — debris bridging the platter to the base creates a mechanical shunt and false low readings.

    Frequently asked questions about the EQB-100

    What are the capacity and readability of the EQB-100?

    Capacity and readability for the EQB-100 are listed in the specification table above.

    What test weight is needed to calibrate the EQB-100?

    A certified weight at or near full capacity with a tolerance no greater than one third of the smallest division, per NIST Handbook 105-1. That is ASTM E617 Class 1 or Class 2 for laboratory resolutions and Class 4 or 6 for industrial capacities. We stock certified weights and can supply the matching class with the instrument.

    How often should the EQB-100 be calibrated?

    Annually for general commercial and industrial use, semi-annually or quarterly under ISO 9001, GMP or HACCP, and immediately after any relocation, suspected overload or impact. Legal-for-trade devices additionally follow the inspection cycle set by the local weights-and-measures jurisdiction.

    Is the EQB-100 legal for trade?

    A scale that determines the price a customer pays must carry an NTEP Certificate of Conformance and be sealed by your state or local weights-and-measures authority. Laboratory-grade accuracy alone does not confer legal-for-trade status, and certification is lost if the seal is broken or the device is moved without re-verification. Ask us to confirm the NTEP number before ordering if money will change hands based on the weight.

    What is the difference between readability and accuracy?

    Readability is the smallest increment the display can show. Accuracy is how close a reading is to true mass and is limited by readability, repeatability (the standard deviation of repeated identical loads) and linearity (deviation from a straight line across the range) taken together.

    How fast does the EQB-100 ship, and can it be repaired?

    In-stock units ship the same or next business day from Cypress, Texas, with free ground delivery to the mainland USA in 1–5 business days. Out of warranty, the common failure points on this class of instrument — load cell or force-restoration coil, keypad membrane, display ribbon and power supply — are all serviceable, and we perform the repair plus a full recalibration in-house rather than returning the unit to the manufacturer.

    EQB-100 manual summary and troubleshooting

    Unpacking and installation

    Unpack on the bench where the instrument will live, fit the platter or pan, and connect the supplied adapter. Level the instrument using the feet until the bubble is centred, then let it power up and warm through before the first weighing.

    Calibration and verification

    Run the span calibration routine with a certified test weight at or near full capacity, then verify with a second weight near one third of capacity. Record both readings and the date in a calibration log.

    Error codes and symptoms

    SymptomCause and remedy
    Unstable / flashing readingAir movement, vibration or an unlevel surface. Move away from HVAC vents and doors, level the bubble, and let the load settle before reading.
    Over-capacity indication (E, EEEE, or ---- )Applied load exceeds capacity, or the platter is fouled. Remove the load, check nothing is trapped under the platter, then re-zero.
    Will not zero at power-upSomething is resting on the pan, or the zero range was exceeded. Clear the pan and power-cycle.
    Calibration fails or rejects the weightWrong nominal mass entered, weight out of tolerance, or the instrument was not warmed up. Confirm the certified value and repeat after warm-up.
    Drifting reading over minutesThermal drift or static. Allow full warm-up, ground the instrument, and use an anti-static device for powders.

    Care and re-verification

    Keep the platter clean and dry, avoid shock loading, store certified test weights in their case and re-verify after any move.

    Need the printed PDF? The official Tor Rey Electronics manual library is at Tor Rey Electronics documentation, or call 832-290-3120 and we will email the exact revision for your serial number. See also the manual & documentation library.